National Thermal Power Corporation Limited - Gujarat

43511459 bids are invited for custom bid for services bmc for electrical maintenance works of main plant offsite areas at ntpc jhanor boq item no. 10.10 to 10.40: maintenance of light fittings/circuits boq item no. 10.10: street light fittings the work includes, 1. finding the fault with the fitting 2. replacement of holders, ballasts, and lamps etc. if found defective. 3. replacement/repair of minor wiring problems. 4. cleaning of fittings with detergent, water or dry cleaning with cloth as per requirement. 5. cleaning of control box, jb, sealing of holes and replacement of tb if required. 6. replacement of fused lamps, ignitors, starters, etc. wherever required. 7. tightness of all the terminals of fixture including all accessories, jb, cable jb etc. 8. maintenance/replacement of any other part associated with lamp circuit but not covered by any other item of boq boq item no.10.20: ftl/gls fittings in offices/light fittings at height less than 4 m this work shall be applicable for fittings installed in offices, on walls, roofs, high bay fittings, fittings installed on boiler etc. up to an height of 4m or more. the work shall involve repair, rectification and cleaning of the fitting. boq item no. 10.30: repair of faulty circuit this work shall apply for such works where the entire circuit is tripping on fault. the work shall include identification of fault and rectification of the same including replacement of parts such as switches, plugs, mcb, etc. & maintenance/replacement of any other part associated with circuit. boq item no. 10.40: lighting system preventive maintenance the work involve preventive maintenance of permanent lighting installations including jbs, light fittings wiring, replacement of defective lamps etc. the job will be given building (installation) wise (for example dm plant, pt plant, cw plant, etc) and for one installation one boq will be executed. boq item no. 10.50: laying of pvc flexible wire the work shall consist of pulling in new al/cu wire (3cx 2.5 sqmm) through existing conduit, casing capping etc and termination to switch/socket. boq item no. 10.60 : installation of recessed gi/pvc conduit with a run of 3cx2.5 sq mm. wire the work shall consist of laying of the recessed conduit. the scope shall also include chipping of brickwork/wall etc. after laying of the conduit, pulling of 3 runs of 2.5 sq. mm. wire shall also be included in this work with end termination to switch/socket, in case of concealed conduiting, plastering and finishing work of the wall will be in the scope of the contractor. if work involve wiring in surface with gi/pvc conduit then 75% of the boq item rate shall be payable. boq item no.10.70 to 10.120 : erection works boq item no.10.70: erection of new light fitting of any type the work shall consist of, 1. erection of fittings along with accessories such as control gear box/ junction box. 2. the work shall also include fabrication of suitable frame/support/clamp/bracket and any civil works required for the installation work. 3. wiring in the existing conduits/casing capping and fixing of switches on the existing switch boards and wire termination to switch/socket shall be covered in the scope. 4. if new conduit laying/switchboard fixing is required, then it shall be covered under other boq items. boq item no. 10.80 :erection of ceiling/wall/exhaust fans the work shall consist of, 1. erection of fan along with ceiling rose etc. 2. providing of clamp, fixing of anchor fastener or any other work required for satisfactory completion of work, including any civil works. 3. wiring in the existing conduits/casing capping and fixing of switches on the existing switch boards and wire termination to switch/socket shall be covered in the scope. 4. if new conduit laying/switchboard fixing is required, then it shall be covered under other boq items. boq item no. 10.90 :erection of 5a/15a switch/switch socket/socket/ fan regulator/mcb/elcb etc. the work shall consist of installation of new or replacement (removal of old/faulty component and installation of new) of existing 5a/15a switch/switch socket/socket/fan regulator/mcb/elcb etc. in existing switchboards. boq item no. 10.100 :erection of single phase switchboards/receptacle up to 20 amps. the work shall consist of, 1. erection of wall mounted/concealed switch board or receptacle. 2. the required civil works shall also be in the scope of the contractor. boq item no. 10.110: erection of db/welding receptacle more than 20 amps and up to 63 amps the work shall consist of 1. erection of db or welding receptacle on wall/structure etc. 2. fabrication of suitable frame including any welding required for the job shall be in the scope of the contractor. boq item no. 10.120 :erection of pole of length exceeding 8.0 meter. the scope of work shall be as follows, 1. the pole shall be supplied by ntpc free of cost. 2. all other inputs/materials required for satisfactory completion of work shall be in the scope of contractor. 3. all masonary work shall be in the scope of the contractor. gravels size not more than one inch. the depth of excavation shall be as per standard. 4.the sketch for tendering purpose is enclosed, however the same is only indicative and final drawing with any minor changes shall be given at the time of execution. 5.driving in of 30mmx3000mm ms earthing rod or burying of 1mx1m sq of 30 mm rod at a depth of 1m around the pole and making connection of the same to the pole. 6. it includes supply & erection of two gi pipes for cable entry to jb. 7.all the works as listed in boq shall be completed to the satisfaction of eic 8 . for erection of pole less than 8 meter height, 50% of boq item rate shall be payable boq item no. 10.130 to 10.170 : dismantling works the work shall include dismantling of items as per the boq. after dismantling, the area shall be properly cleaned and any openings/hole in the wall or ceiling shall be properly sealed using masonary or blanking plates. 10.130 dismantling of light fittings of any type 10.140 dismantling/removal of ceiling/wall/exhaust fan 10.150 dismantling of single phase switchboards/receptacle 10.160 dismantling of db/welding receptacle opto 63 amps 10.170 dismantling of pole exceeding 8 mtr height boq item no. 10.180 to 10.210 : works of temporary nature boq item no. 10.180: temporary installation and removal of light fitting the work shall consist of, 1. installation of fittings/floodlights etc. as per requirement including laying of cable and making the connection at nearest available point. providing of one or more temporary switchboards at the place of installation of temporary light. 2. removal of the fitting and switchboards after the use and returning of the same to store. 3. the works involve temporary laying and rerolling of cable up to 100 meter. boq item no. 10.190:temporary disconnection and reconnection of cables up to 50 mm dia. the scope of work is as follows, 1. disconnection of cables (power, space heater, any other cables), loosening of gland/gland plate and pulling the cable out of terminal box. putting insulation tape over cable ends (lugs). the cable shall be properly supported after removal. 2. gland holes / gland plates shall be suitably blanked. 3. reconnection of cables (power, space heater, any other cables), including reinstallation of gland/gland plate and pulling the cable inside the terminal box. the cable shall be properly supported. boq item no. 10.200 temporary disconnection and reconnection of cables above 50 mm dia. the scope of work is as follows, 1. disconnection of cables (power, space heater, any other cables), loosening of gland/gland plate and pulling the cable out of terminal box. putting insulation tape over cable ends (lugs). the cable shall be properly supported after removal. 2. gland holes / gland plates shall be suitably blanked. 3. reconnection of cables (power, space heater, any other cables), including reinstallation of gland/gland plate and pulling the cable inside the terminal box. the cable shall be properly supported. boq item no. 10.210 temporary connection and disconnection of loads such as welding machines/temp pumps/ any other loads the work shall consist of, 1. issuing of wire/cable from dept stores. 2. making connections of the temporary installation, both sides if required. 3. disconnection of cable after completion of work and returning of the same to departmental store. 4. the works involve temporary laying and rerolling of cable up to 100 meter. boq item no. 10.220 lighting panel/welding receptacle. the work will consist of, 1. cleaning of panel. 2. checking of tightness of power and earth connections and rectification of the same including minor repairs. 3. replacement of any defective parts and missing parts such as switch handle, screws etc. boq item no. 10.230:painting of poles the scope of work shall consist of , 1. cleaning of old paint/rust using steel wire brush, emery paper of buffing as per the condition of the pole. 2. application of red oxide primer as touch up or on the entire length, depending on the condition of the original paint and metal surface. 3. application of one coat of aluminium paint using paint brush. second coat of aluminium paint may have to be provided only in case of highly corroded poles. 4. repainting of pole identification number. 5. for pole painting of height 4m or less, 25% of boq item rate shall be payable. boq item no.10.240: preventive maintenance of permanent lighting system of plant buildings 1. all electrical fittings including tube light fixtures, gls fixtures and local switch boards shall be cleaned and inclusive of any minor repair like replacement of tube light, gls lamp, switches, mcb, elcb etc. 2. earthing in all the switchboards shall be checked and neutral to earth voltage shall be properly recorded and documented. 3. damaged ceiling rose/ blanking plates shall be replaced 4. repair of any minor burnt wiring / points 5. tightness shall be checked at all the switchboard points 6. all the mcbs and elcbs shall be checked . the elcb shall be checked for correct operation. 7. preventive maintenance of ceiling fans including checking & replacement of fan fixing bolts, rods etc, cleaning of blades and replacement of capacitors if required. 8. pm of distribution board/junction boxes : cleaning of box, wire tightness checking, relugging of wires if required, replacement of mcbs if required and sealing of holes. this boq item is applicable for facility building, ich, ccd, fqa and central store and old store. one boq item shall be executed for pm of each of above said buildings. boq item no.10.250 to 10.260: earthing works boq item no. 10.250: laying of gi wire. the work shall consist of laying gi earthing wire along the wall/structure/existing conduit/casing capping etc. the wire shall be properly clamped at intervals not exceeding 800 mm. boq item no. 10.260: laying of earth flat the work shall consist of laying of gi earth flat along the wall/structure etc. the earth flat shall be weld jointed as per requirement. all the works including welding of the earth flat, making of holes for connection, providing supports at regular intervals ( not exceeding 800 mm ) shall be in the scope of the contractor. boq item no.10.270 to 10.320 : periodic maintenance of switchgear / busduct boq item no. 10.270 15.75 kv isolated phase generator bus duct the work shall consist of, 1. cleaning of busduct conductor, enclosure and insulators. 2. tightening of all joints. (cleaning of the same, if required. ) 3. replacement of damaged gaskets. 4. disconnection and reconnection at transformer end, if required. 5. checking/cleaning/tightening of earthing connections. 6. carrying out air leak test and attend the leakages. boq item no. 10.280 one panel of switchgear the work shall consist of carrying out the following jobs in one panel of 415/6.6 kv switchboard. 1. cleaning of busbar chamber 2. cleaning of panel from inside and outside using vacuum cleaner, cloth etc. 3. tightening of all joints. 4. cleaning and checking of all the panels. 5. replacement of any defective parts. boq item no. 10.290 6.6 kv sf6 / 415 v acb the work shall consist of, 1. cleaning, tightness, lubrication and testing of breakers 2. replacement of any defective parts. 3. cleaning of breaker cubicle and its control cubicle. 4. tightness of power and control cables. 5. assistance in electrical testing. boq item no. 10.300 generator accessory cubicle the generator accessory cubicle is divided into following chambers, 1. pt and sp cubicle. 2. earth switch and starting isolator cubicle. 3. excitation transformer cubicle. 4. control cubicle. 5. bus duct pressurisation compressor cubicle 6. cooling air fan cubicle the work shall consist of cleaning, preventive maintenance and testing of above listed enclosures and its equipment. boq item no. 10.310 generator terminal box the work shall consist of cleaning and tightness checking of generator terminals. the connections may also have to be opened for carrying out electrical tests, if required. boq item no. 10.320 breakdown maintenance of switchgear panel 1. replacement of power contactor, control control contactor, o/l relay and fuses if required 2. power cable crimping if required 3. replacement of current transformer, ammeter, voltmeter, and selector switches indication lamps etc if required. boq item no. 10.330 periodic greasing of motors: the scope of work is as follows, 1. issue of grease gun and grease from store. 2. greasing of motor as per instructions. 3. draining of old grease and cleaning of the work area. boq item no. 10.340 to 10.400 : preventive maintenance works periodic inspection of lt motor of various rating (10.340 to 10.400) the scope of work is as follows, 1. checking of cleanliness and tightness of power/control cables at motor and feeder end. 2. cleaning of motor body, motor cooling fan, terminal box etc. 3. cleaning and tightness check of feeder module/breaker. 4. measurement of wr and ir of motor and recording in prescribed format 5. measurement of space heater current and recording in prescribed format 10.340 lt motor(<=2.2kw) 24w chks 10.350 lt motor(>2.2 5.5kw) 24w chks 10.360 lt motor(>5.5 18.5kw) 24w chks 10.370 lt motor(>18.5 37kw) 24w chks 10.380 lt motor(>37 55kw) 24w chks 10.390 lt motor(>55 90kw) 24w chks 10.400 lt motor(>90kw) 24w chks boq item no. 10.410 periodic maintenance of batteries the station has lead acid batteries as per the following details: 1. 220 v batteries – 5 nos, each having 108 cells 2. 24 v batteries – 12 nos, each having 13 cells 3. 24 v battery – 2 nos, each having 26 cells 4. 48 volt battery – 2 nos each having 24 cells 5. 4 nos 12 v batteries for diesel engine. the work shall consist of two parts. part 1 shall consist of carrying out the following work on all working days 1. recording of parameters of 10 % pilot cells of all the batteries in the format given by the area engineer. 2. topping up with dm water as per requirement. 3. cleaning of cells after taking the readings. 4. checking of safety devices in the battery room. part 2 – shall consist of carrying out the following works once in every month 1. recording of battery parameters of all cells of each battery bank listed above in the format given by the area engineer. 2. topping up all the cells with dm water up to the normal level. 3. cleaning of all cells of battery banks. 4. checking and maintenance of safety devices in the battery room. boq item no. 10.420 periodic replacement of brushes • at our unit we have 3 nos gas turbine generators and one steam turbine generator. • the gas turbine generator has 12 brush holders each having 2 nos carbon brushes. the generator also has 4 nos. shaft earthing brushes mounted on 2 nos brush holders. • the steam turbine generator has 16 brush holders having 6 nos carbon brushes and 16 brush holders having 4 nos carbon brushes. the generator also has 4 nos. shaft earthing brushes mounted on individual brush holders. • the work shall involve removal of brush holders, measurement of brush length, cleaning of brush holder, replacement of carbon brush, if required and refixing of the brush holder. boq item no. 10.430 periodic cleaning of brushgear. the scope of work is as follows, 1. removal of all the brush holders and carry out the works as in item no. 7.10 2. clean the brush gear enclosure, slip ring, terminals etc. using cloth, vacuum cleaner etc. boq item no. 10.440 periodic maintenance of eot cranes the scope of work is as follows, 1. measurement of ir and wr of all the motors 2. functional checks of crane by pendent switch for all directions and cut off by limit switches to be ensured. 3. limit switches and push buttons of pendent switch to be replaced if found defective 4. proper cleaning, tightness and cable dressing of junction box. boq item no. 10.450 to 10.490 : motor removal and re installation the scope of work shall consist of removal of motor from foundation and reinstallation of new/repaired motor in its place. the works shall consist of the following, 1. disconnection of cables (power, space heater, any other cables), loosening of gland/gland plate and pulling the cable out of terminal box. putting insulation tape over cable ends (lugs). the cable shall be properly supported after removal. 2. gland holes / gland plates shall be suitably blanked. 3. disconnection of earthing connections. 4. removal of canopy or any other part necessary for removal of motor. 5. removal of foundation bolts, lifting of motor using proper lifting tools and shifting of the same to workshop. 6. all the works listed above shall be done in reverse order for re installation. 10.450 lt motor (>5.5 18.5kw) instal/remove 10.460 lt motor (>18.5 37kw) instal/remove 10.470 lt motor (>37 55kw) instal/remove 10.480 lt motor (>55 90kw) 10.490 lt motor (>90kw) instal/remove boq item no 10.500 :motor removal, testing & reconnection 1. motor removal by cable disconnection and shifting to workshop (if required) 2. motor trial run at test bench by temporary electrical connection of motor 3. motor reinstallation and cable connection 4. replacement of motor if the removed motor is found defective in trial operation all cable disconnection & reconnection, motor installation on test bench, removal from test bench are covered in this boq. boq item no.10.510 to 10.560 : servicing of lt motors the common scope of work for item 10.510 to 10.560 is as follows, 1. motor cable disconnection and shifting to workshop 2. clean the motor body. 3. remove the coupling half/pulley/hub, motor cooling fan cover, motor fan care fully. 4. remove the bearing housing etc.; remove old bearing using bearing puller. 5. check the motor leads; repair if required. check and clean rotor. check and repair overhang ties. 6. preheat the motor in oven and apply varnish. bake it in oven for required time. 7. reinstall new bearing as per the standard practices, lubricate the same and box up the motor in reverse order. 8. motor painting as per item no 10.600 to 10.630 9. motor trial in test bench in workshop (installation in test bench, cable connection etc) 10. reinstallation of motor in service position and cable connection 11. sufficiently skilled and experienced manpower shall be deployed for this work. at least one fitter shall always be involved in this work. 12. necessary care shall be exercised to prevent any damage to the motor parts. the contractor shall be responsible for any damages to the equipment because of poor workmanship and the cost of repair for such defects shall be recovered from the contractor. 13. boq items covered under above scope of work as follow: 10.510 elltm01oh000 lt motor (<=2.2kw) serv 10.520 elltm03oh000 lt motor (>5.5 18.5kw) serv 10.530 elltm04oh000 lt motor (>18.5 37kw) serv 10.540 elltm05oh000 lt motor (>37 55kw) serv 10.550 elltm06oh000 lt motor (>55 90kw) serv 10.560 elltm07oh000 lt motor (>90kw) serv boq item no.10.570: servicing of single phase and three phase ceiling/wall/exhaust/air cooler fans and air cooler pumps motors upto 1 kw. the scope shall consist of : 1. removal of electrical connection and removal of fan from place of installation and shifting of the same to workshop. 2. cleaning of fan with cloth or soap solution as per requirement. 3. cleaning and regreasing of the bearings. replacement of bearings, if required. 4. replacement of any other parts such as capacitor as per requirement. 5. reinstallation of the same or new fan. boq item no.10.580: transformer maintenance works. the scope of work shall be as follows: 1. disconnection of terminal connections and reconnection of the same after maintenance works. 2. cleaning of the transformer and all its accessories 3. replacement of gasket of primary & secondary terminal 4. any repairs of minor nature to attend leakages etc. 5. assistance in electrical testing of transformer. 6. for testing, the contractor’s scope shall be limited to shifting of the testing instruments from electrical lab to site, making connections for the tests and assistance in checking of protection devices and other instruments. after completion of tests the instruments shall be disconnected and returned back to the lab. 7. any other works not listed above but necessary for checking the transformer shall be in the scope of the contractor. boq item no. 10.590 :painting of control panel / switchgear the scope of work shall consist of , 1. masking off of lamps, relays, meters, glass/acrylic surfaces, switches etc. 2. cleaning of metal surfaces using cloth/emery paper etc. 3. application of red oxide primer as per requirement, using paint brush. 4. application of synthetic enamel paint using spray gun. 5. removing of masking 6. repainting of identification numbers on all modules, panels etc. the scope also includes misc. painting jobs , letter writing in panels, earth pits etc and payment shall be made on per square meter basis. boq item no. 10.600 to 10.630:painting of motors. the common scope of work for item no 10.600 to 10.630 shall consist of: 1. painting of motors in situ or in workshop. 2. removal of fan cover and motor cooling air fan. 3. cleaning of motor body using wire brush/scraper/solvent etc. 4. application of one coat of red oxide primer. 5. application of one or two coats of synthetic enamel paint using paintbrush or spray. 6. repainting of identification numbers. 7. item covered under above said sow are as follow: 10. 600 elltm01gn750 lt motor (<=2.2kw) painting 10. 610 elltm05gn750 lt motor (>37 55kw) painting 10. 620 elltm06gn750 lt motor (>55 90kw) painting 10. 630 elltm07gn750 lt motor (>90kw) painting boq item no. 10.640:painting of transformer upto 2 mva the scope of work shall consist of: 1 complete cleaning of oil stained area of transformer with light detergent powder and overall cleaning of transformer 2. masking of glasses/gauges etc 3. apply red oxide after cleaning 4. spray painting in all parts of transformer i.e. tank, radiator, conservator tank, marshalling box etc. 5. any lettering, marking if required will be in the scope of contractor 6. after successful completion of painting, removal of masking, cleaning of area etc. boq item no.10.650 : collection of oil sample the scope of work shall consist of: 1. collection of oil sample from transformer, motor, oil drum etc. in ss/pvc bottles. 2. the bottle shall first be rinsed properly and then the sample shall be collected. 3. the waste oil shall be collected in plastic container and disposed in identified waste oil drum. 4. the spilled oil during the process shall be cleaned. boq item no.10.660: replacement of air blower unit of office a/c the scope of work is as follows, 1. removal of false ceiling. 2. removal air blower, removal of motor, refixing of new motor and reinstallation of the air blower. or else, installation of a new air blower. 3. refixing of false ceiling. 4. commissioning of the air blower. boq item no.10.670: cleaning of tube type coolers the scope of work shall consist of, 1. cleaning of tube type coolers of motors/stator cooling/seal oil cooling system. 2. the coolers may be required to be dismantled and shifted to maintenance bay for cleaning. 3. the work shall consist of opening of water boxes, cleaning of coolers using water and nylon wire brush, boxing up after completion of cleaning. 4. carrying out of hydro test if required. 5. reinstallation and re commissioning of coolers. boq item no.10.680: drawal of material from stores. the scope of the contractor shall consist of, 1. this item shall apply only for items, which are drawn for storage in departmental stores. any material drawn from stores for completion of assigned job shall be a part of the job and will not be included in this item. 2. transport the material form central stores to site/dept stores or back to central store. 3. transport of material shall be done using hand pulled trolley. for heavy loads, fork lift may also be provided. 4. the work will also include loading and unloading of material. boq item no.10.690: drawal of gas cylinder from stores. the scope of the contractor shall consist of, 1. transporting of empty cylinder to the central store and filled cylinder from store to site 2. forklift shall be provided for carrying out this job. 3. the work will also include loading and unloading of material. boq item no.10.700: misc minor maintenance jobs the scope shall consist of , 1. the jobs which are not covered in boq items shall be part of this item 2. contractor has to deploy skilled & unskilled manpower for the jobs as per requirement or as directed by eic 3. the duration of jobs shall be max. one day and additional quantity will be considered if the work goes beyond one day. boq item no.10.710: station earthing testing the scope consist of : 1. assistance in station earth resistance testing 2. this includes earth pits in main plant, offsites and store area. 3. the earth resistance meter will be provided by ntpc. boq item no. 10.720 :battery capacity test the scope of the contractor shall consist of , 1. shifting of load to battery location and connection & disconnection of load 2. hourly recording of specific gravity, cell voltage and discharge/charge current for 24 hrs a day. 3. top up of dm water based on requirement 4. cleaning of cells and battery terminals 5. removal of load and shifting to specified place 6. contractor has to deploy manpower in shifts for 24 hrs and no overtime shall be payable for the job boq item no.10.730 :assistance in grp, excitation and starting device testing the scope shall consist of, 1. shifting of secondary injection kit, auto transformer, measuring instruments and test leads to relay location. 2. power supply arrangement 3. deployment of one technician during entire test period. 4. return of all the materials to store after completion of testing. boq item no.10.740 :excitation panel/ starting device panel preventive maintenance 1. cleaning thyristors, cooling fans, fcb cubicle, control cubicle 2. cleaning of cards and replacement if required 3. hot air blower in control panel if required boq item no.10.750 to 10.760 : assistance in works 1. providing manpower for any other job not specifically described in boq/job descriptions contractor shall provide manpower on man days basis. the manpower may be required to come in shifts as well. 2. however, no overtime payment shall be applicable to manpower deployed in shifts 10.750 skilled manpower 10.760 unskilled manpower boq item no.10.770 : cleaning of solar pv cell panel 1. cleaning of solar pv cell panel in 100kw roof top solar of plant buildings, bbp school in township with water and cleaning of the surface with wiper/brush etc. 2. any material/consumable’s for attending the above job i.e. brush , detergent etc will be in the scope of agency 3. cleaning to be done twice in a month and it will be treated as one quantity of boq boq item no.10.780: station earthing system maintenance/repair 1. measurement of earth resistance 2. thoroughly cleaning of earth pit 3. pouring of water for two to three hours 4. mix the rock salt, bentonite with water and pour into the earthing pit 5. leave for 8 to 12 hours 6. measure earth resistance 7. if earth resistance not in limits repeat the step no 4 to 5 boq 10.790: deployment of technical assistant engineer the scope of work under this item includes deployment technical assistant in emd for assisting ntpc officials in electrical maintenance works and all other works pertaining to emd at ntpc jhanor. following technical assistant to be deployed senior technical assistant 01 nos i. the senior technical assistant (01no) should be a holder of degree in engineering/ technology in electrical discipline with minimum 2 years experience in related fields. ii. the working period of the deployed assistants shall be 09:00 am to 06:00 pm and in case of requirement, he has to work beyond the defined period for which no extra compensation will be made. iii. he shall be entitled to avail all the closed holidays of ntpc jhanor (normally 08 days) and 01 normal weekly off of sunday. in case of requirement weekly off of sunday can be replaced with any other working day. in case of absent other than as mentioned above deduction from one month cost shall carried out on prorata basis (considering 26 days as 01 month). iv. the technical assistants shall use his own vehicle and mobile phone for supervision of work in plant area. v. eic has the right to interview the assistants before deployment and original qualification certificates to be produced for verification purpose. vi. performance of the assistants shall be regularly monitored by eic and deployment may be terminated at any time by giving one month notice and ntpc does not have to assign any reason for the termination. vii. to maintain the quality of work contractor shall pay a minimum of rs:18,000/ basic + pf + insurance + mobile allowance (rs:700/ pm) + conveyance allowance (rs:3000/ pm) + hra (20% of basic) + bonus to each assistant per month or as per minimum wages and other statutory requirements whichever is higher. 01 quantity in this boq means deployment of 01no. (one number) of technical assistant for 01 (one) month. boq 20.10: amount linked to safety aspects 1. safety aspect has been dealt in detail in the document on safety clauses for operation & maintenance contracts, which shall be the basis for regulation and use of safety devices. 2. other details are as per clause no 8 of special terms and conditions. 3. amount linked to safety aspect will be released only after compliance to all safety rules and regulations defined in the contract i.e. scope of work and special terms & conditions. the decision of eic shall be final in this regard. total quantity :...

Surat Municipal Corporation - Gujarat

42967089 setc of vt pump set & related mechanical & electricalequipments at variav water distribution station ( new ) ofsurat municipal corporation. 1 non clog submersible pumps with guide rail, auto coupling etc. 2 horizontal non clog pums 3 vertical non clog pumps 4 vertical turbine pumps 5 horizontal splitcase pumps 6 ceramic filtration membrane 7 motor 8 tefc motor for mechanical screen 9 submersible pumps / dewatering pump / desilting pumps 10 screw / positive displacement type pump 11 dosing pumps12 bearings 13 air blowers – screw type 14 centrifugal / turbo type air blower 15 non return valve 16 dual plate reflux check valve 17 ball type non return valves 18 sluice valve & air valves 19 butterfly valve 20 metallic expansion bellows 21 electrical actuator 22 sluice gate 23 c.i. fittings 24 e.o.t. crane 25 chain pulley block & electric hoist 26 gear box 27 pressure gauge 28 frp chequered plate / gratings 29 filter nozzels 30 fabrication steel structures / plates 31 tools & tackels 32 gate 33 knife edge gate valves 34 sampling pumps 35 air blower 36 agitator / stirrer / mixer 37 air compressors 38 pprc tube 39 sludge thickener / clariflocculator 40 fasteners 41 float type flow indicator 42 centrifuge feed pumps 43 centrifuge 44 surface aerators 45 bearings 46 pipes 47 g.i. pipes 48 m.s. pipes 49 cast iron pipes and fittings 50 hdpe pipes 51 grp pipes 52 frp pipes & accessories 53 pvc sheets 54 paint 55 automatic mechanical course bar screen 56 gear box for mechanical screen & for actuator57 process equipments 58 orifice plate 59 float / buoyancy switch 60 fine screen 61 cpvc / upvc pipe 62 fastners 63 float type flow indicator 64 others 65 refrigerator 66 air conditioners 67 hot air blower: electrical items 1 h.t vcb panel 2 transformer 3 ht protective relays 4 l.t power cable 5 h.t power cable 6 h.t, lt jointing kits 7 lt switchgears 8 soft starters 9 mcb, elcb 10 electronic timers, time switch 11 manual change over switch 12 fuses 13 led indictors 14 push button 15 selector switch 16 epoxy cast resin c.t 17 motor protection device 18 cable termination kit ( lugs & glands ) 19 digital meters 20 analog meters 21 apfc relays 22 capacitor 23 terminal connector 24 online ups 25 smf battery 26 engine of d.g. set 27 alternator of d.g.set 28 panel board manufacturer 29 h.t connectors 30 cable trays 31 auxiliary control relay 32 dc power source 33 computer system 34 inverter 35 led19 digital meters 20 analog meters 21 apfc relays 22 capacitor 23 terminal connector 24 online ups 25 smf battery 26 engine of d.g. set 27 alternator of d.g.set 28 panel board manufacturer 29 h.t connectors 30 cable trays 31 auxiliary control relay 32 dc power source 33 computer system 34 inverter 35 led36 vfd ( variable frequency drive ) lighting material / items 1 pvc insulated copper wire 2 2 x 40 w fl luminaries with lamp 3 fittings with indoor and outdoor luminaries 4 led luminaries with lamp 5 sont lamp 6 fluorescent light fixture etc 7 distribution boards 8 mcb 9 switches, plugs 10 cable 11 ceiling fan 12 exhaust fan 13 make of the ballast: instrumentation 1 water quality analysers ( turbidity, free residual chlorine, etc. ) 2 ultrasonic type level / diff. level / loh & rof / open channel flow transmitter 3 electromagnetic flow meter ( insertion type flow meter ) ( full bore ) 4 ultrasonic portable flow meters ( for pipeline ) 5 differential pressure / pressure / temperature transmitter 6 pressure switch 7 float level switch 8 electric actuators 9 pneumatic cylinders 10 solenoid operated valve 11 air filter regulator 12 limit switches 13 programmable logic controller ( plc ) system 14 a online ups 14 b inverter 15 smf batteries 16 lt / instrument power & control cables 17 signal ( analog ) cables 18 communication cables 19 cast aluminium junction boxes 20 air conditioners 21 office furniture 22 panel enclosures 23 alarm annunciator 24 instrument valves and manifolds, tube fittings, pneum. brass fittings 25 miniature relay 26 indication pilot lamps ( led type ) 27 push button / selector switch ( with no / nc element ) ...

Dudhsagar Dairy - Gujarat

42846717 tender for purchase enquiry for materials 3936507 848330 00 jem 20 14 sp,igubal spherical ball 30 ea 31.03.2024 mm02 spg000011 2 3006228 850151 11 crate washer motor(hot air blower) 2 ea 31.03.2024 mm02 spe000016...

Ministry of Housing and Urban Affairs - Gujarat

41205415 bids are invited for elec tools lot5 4 channel thermometer with probes , digital thermometer with probes , anemometer , dc power supply , drill machine battery operated cord and cordless , hot air blower , straight grinder , angle grinder , bench drill machine , pneumatic impact wrench , temperature controlled hot air gun , battery operated wrench , battery operated screw driver , tool box electrical total quantity : 62...

Ministry Of Petroleum And Natural Gas - Gujarat

41178891 bids are invited for laboratory use adjustable micro pipette 10 to 100 micro litre with box of 100 tips minimum , adjustable micro pipette 100 to 1000 micro litre with 100 tips , variable volume auto pipette cap 10 ml with 15 tips , aluminium foil , aluminium bottle 1 litre , aluminium bottle 2 litre capacity with handle , aluminium bottle 250ml , beakers plastic 1000 ml capacity , beakers plastic 2000 ml capacity , beakers plastic 5000 ml capacity , bottle brush nylon , bottle top dispenser 2.5 to 30 ml , bottle top dispenser 1.0 to 10 ml , bottle top dispenser 0.5 to 5 ml , beaker tong , bubbler silicon type small , bubbler silicon type big , calculator 12 digit solar battery , forceps ss , forceps straight , duster cotton lint free , filter paper glass micro fibre , filter paper 0.45 micron , flask brush nylon , hammer , hot air blower , jerricane plastic 10 liter , jerricane plastic 5 liter , plastic bottle with cap 125 ml , plastic bottle with cap 250 ml , plastic bottle with cap 500 ml , plastic bottle with cap 1000 ml , plastic measuring cylinder , plastic tray 30 cm width and 45 cm length , plastic tray 30 cm width and 30 cm length , plastic bucket , plastic bucket jali type , syringe plastic with needle 5 ml , syringe plastic with needle 10 ml , scissors straight ss tailor type , spatula one end spoon and one end flat , sterilized cotton roll 1 kg procurement of miscellaneous items for general total quantity : 1137...

Dudhsagar Dairy - Gujarat

40521084 sale of old plant machinery and equipment’s ( on as is, where is, what is basis ) of mehsana district co operative milk producers’ union ltd., dudhsagar dairy, highway, mehsana. filled crate conveyer, asset no 3000000102 empty crate conveyer, asset no 3000002185 auto milk pouch crate conveying system, asset no 3000000757 crate washer, capacity:1000 crate / hr, asset no 3000005175 carton conveyor 1, conveyor sr no 1, asset no 3000000089 carton conveyor 2, conveyor sr no 2, asset no 3000000779 carton conveyor 3, conveyor sr no 3, asset no 3000002851 serum separator ( ssb 1 ) , asset no 3000003758 and allied item diffuser no 1, cold store 1a, asset no 3000000112 motor, asset no 3000000211 motor, asset no 3000000212 diffuser no 1, pouch cold store 1a, asset no 3000002867 motor, asset no 3000004221 diffuser no 2, pouch cold store 1a, asset no 3000002868 motor, asset no 3000003611 diffuser cold store, asset no 3000002198 cooling tower type frp induced draft counter f, asset no 3000001164 hot weld cold weld tank, asset no 3000003346 butter cutter for ghee section with two pneumatica. asset no 3000003285 agitator f / butter milk vat 1 sset no 3000002133 and allied item water cooler ( 150 ltr ) , asset no 4000000397 water cooler ( 120ltr ) , asset no:4000000143 water cooler ( 150 ltr ) , asset no 4000000593 water cooler ( 120ltr ) , asset no:4000001394 water cooler ( 120ltr ) , asset no:4000001408 water cooler ( 120ltr ) , asset no:4000001703 water cooler ( 120ltr ) , asset no:4000001704 water cooler ( 120ltr ) , asset no:4000001753 automatic washing machine ( 6.5kg to 7 kg ) , asset no:4000002132 ( qty:2 ) electric instant geysers ( cap.3 ltr ) , asset no:4000002182 ( qty:3 ) water cooler ( 150 ltr ) , asset no 4000002129 qty:2 ) ro system, asset no:4000002130 water cooler ( 150 ltr ) , asset no: not available in list water cooler ( 150 ltr ) , asset no: not available in list refrigerator asset no: 3000005029 and allied item n3 dehumidifier ( d 101 ) for vibro cold air supply asset no. 3000000803 l t power distribution electric penal board old kilosker penal ) asset no: not in asset register l t power distribution electric penal board old gram penal ) asset no: not in asset register fax machine, type laser , make panasonic, model kxf, mba electronics, asset no 4000001022 1nos bicycle , cycle use for accounts, asset no 6000000052 spiral conveyor at uht section, asset no 3000008923 submersible pump with motor ( complete set ) , asset no 3000000398 coal fired boiler ( cap:300 kg / hr gt 1748, asset no 3000004127 transformer 315 kva, make paston s.s. ghee vat refrigeration electric panel main incomer electric panel general electric panel reception electric panel amonia compressor 9, qty 01 nos, asset no 3000009015 milko scan minor 6, make foss electrict sr no 520013375 , asset no 3000002671 eko milk ultra pro milk analyzer for fat analysis sr no 127922 , asset no 3000005302 funke gerber centrifuge , asset no 3000000044 frp induced draft cooling tower without basin, man, asset no 3000001875 bt to high heater pump ( pp 1 ) , asset no: 3000001821 vacuum pump with motor , equiv.to sihi make model:le asset no :3000005770 vacuum pump with motor , equiv.to sihi make model asset no :3000002589 vacuum pump with motor , equiv.to sihi make model:le asset no :3000005617 vacuum condensor vacuum pump 1 ( vp 3 ) asset no :3000004430 motor for bt to high heater pump ( pp 1 ) asset no:3000004259 can loading conveyor 1, f / dock 1 asset no:3000004119 motor f / ( can loading conveyor 1 ) asset :3000004251 motor f / ( can loading conveyor 1 ) asset :3000004895 one exhaust fan for ghee packing vihar asset no:3000007945 can washer with all equipment accessories and contr asset no:3000003281 detergent pump f / can washer 1 asset no:3000004424 dump tank 1 f / dock 1 asset no :3000000489 pre ranse pump f / can washer 1 asset no:3000005058 hot water pump f / can washer 1 asset no:3000005059 dump tank 2f / dock 2, asset no:3000000598 can scrubber 1 f / dock 1 asset no :3000000011 400 amp oil circuit breaker no 2, asset no 3000004674, make crompton & greaves 400 amp oil circuit breaker no 1, asset no 3000003428, make crompton & greaves refrigerator asset no: 3000007349 mbrt waterbath asset no 3000007411 milk weigher& dump tank outdoor unit 01 nos asset no:3000008987 can tripping bar 01 nos asset no:8002000515 / 3000008987 gravity can roller conveyor – 01 nos asset no:8002000515 / 3000008987 milk cab scrubber – 02 nos asset no:8002000515 / 3000008987 can washing trough – 02 nos asset no:8002000515 / 3000008987 can drip saver 01 nos asset no:8002000515 / 3000008987 can washar with acessaries asst no : 3000000062 filter : 3000000119 motor f / hot air blower : 3000000264 motor f / exhaust fan :3000000265 detergent pump:3000001136 pre rinse pump :3000001827 exhaust fan :3000002884 hot air blower:3000003461 attersing ring pump:3000003825 motor for lead conveyor:3000004908 hot plate – 02 nos asset no:3000007983 gerber centrifuge – 02 nos asset no:3000007983 circulatory water bath – 02 nos asset no:3000007983 serological waterbath – 01 nos asset no:3000008095 waterbath – 01 nos asset no:3000008095 d.g.set – 01 ( qty.01 nos ) asset no:8002000515 / 3000008987 d.g.set – 02 ( qty.01 nos ) asset no:8002000515 / 3000008987 bulk cooler 8 kl milk tank 1 nos asset no:3000009977 condenser unit 2 nos, panel bord, milk pump, dump tank ( sakari socity ) , asset no:3000009935 voltage regulator stabilizer ( sakari socity ) , asset no:3000009933 condenser unit 2 nos, panel bord, milk pump, ( balva 2 socity ) , asset no:3000000043 ss dump tank, 200 liter capacity, ( balva 2 socity ) , asset no:3000000483 voltage regulator stabilizer ( balva 2 socity ) , asset no:3000001774 condenser unit 2 nos, panel bord, dump tank ( miyasana socity ) , asset no:3000009936 ss milk pump 1.5 hp, ( miyasana socity ) , asset no:3000009937 and allied item gas geyser, asset no:4000002120 electric water geyser, 3 ltr, wall moun 230 volt, ac, watt:30000w , asset no: 5002000312 electric water geyser, 3 ltr, wall moun 230 volt, ac, watt:30000w , asset no: 5002000312 old panel board with main s / w & earth s / w old panel board ( big & small ) approx size:1.5x3ft old panel board approx size:4x6ft with main s / w with feeder old panel board approx size:4x6ft with main s / w with feeder panel board, old type sodium / potassium analyzer for mehsana q.a , make or, asset no.: 3000006804 8000 ltr ss milk tank for bmc, asset no 3000009977 compaq deskpro 400 mhz, asset no 7000000342 hcl p 4.1, asset no 7000000344 dot matrix printer model:wep hq1070+dx:spec:d, asset no 7000000870 cisco 31721 remote router, asset no 7000000351 icim pc , asset no 7000000464 printer l 1050+dx, asset no 7000000348 on line ups, power rating 2 kva with 100%loadin, asset no 7000000402 computer cpu, without monitor, make zenithconfigur, asset no 7000000715 hcl computer system, intel pentium iv 2.26 ghz, 84, asset no 7000000478 dot matrix printer model:wep hq1070+dx:spec:d, asset no 7000000426 dot matrix printer model:wep hq1070+dx:spec:d, asset no 7000000651 modem d link 56.6 kbps, asset no 7000000331 dot matrix printer model:wep hq1070+dx:spec:d, asset no 7000000220 ammonia receiver qty 02 nos, asset no:3000009017 lawn mower for new developed lawn frass piot, asset no:3000007926 gear box for aerator, asset no:3000000836 aerator, asset no 3000000696 handgrinder, 230volt, 50hz, 680watts, 12000rpm asset no:3000004644 refrigerator, make:kelvinator model khel 173lc, asset no:3000001331 molasses flow meter, asset no:3000005601 molasses flow meter, asset no:3000005602 molasses flow meter, asset no:3000005805 molasses flow meter, asset no:3000005865 pellet cooler fan, asset no:3000007092 pellet cooler fan, asset no:3000007228 cycle use for , watchman for boriyavi , & jagudan cfpl, asset no:6000000041 fan :ceiling, asset no:4000001756 refrigerated air dryer, asset no:3000007072 refrigerated air dryer, asset no:3000007073 water cooler for cfp jagudan , asset no:4000002150 air compressor digital burette, asset no:3000008082 portable bag stitching machine, asset no:3000005638 portable bag stitching machine, asset no:3000005786 portable bag stitching machine, asset no:3000005919 stitching machine stitch well , qualtitex modal no: sd, asset no:3000006785 stitching machine stitch well , qualtitex modal no: sd, asset no:3000006809 submercibal pump set for 10 x 1000 tube well, asset no:3000007397 spare motor for pellet mill, asset no:3000005850 spare motor for pellet mill, asset no:3000007243 motor 1 hp motor 1.5 hp motor 3 hp motor 5 hp motor 7.5 hp motor 10 hp motor 12 hp motor 15 hp motor 20 hp motor 25 hp motor 40 hp snu gear water pump vibrator solar street light system as per po ( comm / jagudan, asset no:5002000086 soft starter panel, asset no:3000007004 siren o.c.b c.f.p jagudan ( comm / jag / pur / 16769 ) , split a.c mac, asset no:4000001921 split type air conditioning unit for control room, asset no:4000001932 window ac dot matrix printer 132 column 24 pin model : wep h asset no:7000000904 dot matrix printer 132 column 24 pin model : wep h asset no:7000000905 ups for control & plc, asset no:7000000893 ups for control & plc, asset no:7000000947 zerox m / c projecter gas burner, asset no:3000005695...

Department Of Labor And Employment - Gujarat

34092997 bids are invited for soldering iron 10 watt , soldering iron 25 watt , pcb holder and pcb stand for mobile , blade cutter , nose cutter 130 mm , tweezers 6 inch , multimeter digital 4 digit , screwdriver kit for mobile reparing , different types mobile opener , magnifying glass with stand and led lamp dia tester trade at iti valod 50mm , rework station hot air blowers for mobile , batterybooster for mobile reparing , different types of test jig box04 types for mobile reparing , ultrasonic cleaner for mobilereparing , bga kit for mobile reparing 9 to 15v 2 amp , dcpower supply for mobile reparing , digitized touch screenglass separator machine up to 120 degree celsiustool and equipment for smartphone technician cum app total quantity : 236...

Ministry of Housing and Urban Affairs - Gujarat

33622432 bids are invited for 4 channel thermometer with probes , digital thermometer with probes , anemometer , dc power supply , drill machine battery operated cord and cordless , hot air blower , straight grinder , angle grinder , bench drill machine , pneumatic impact wrench , temperature controlled hot airgun , battery operated wrench , battery operated screwdriver , tool box electrical , battery tester total quantity : 66...

Department Of Labor And Employment - Gujarat

30483136 bids are invited for weather monitoring station temperature range : 10°c to90°c, relative humidityoperating range0 to 95%, wind speed sensor speed : 0 to20m / s resolution 1m / s , winddirection, rainfallbucketcollector, solar radiation, uvindex, atmospheric pressure, air quality, pm2.5, gsm basedcloud connectivity, applicationsoftware for dashboard forremote monitoring and analysis.power supply battery :12v / 42ah solar panel : 100w , usedwatertreatmentsolarplantdemonstrator kit 1 liter capacity , demonstration kit for windgeneration ( wind turbine with blower ) 300 w , sun path finder designing of solar power plant, architectural, engineering, solar, and ecological applicationscolorblue black , solar wind and hybrid power plant 1 kw cumulative type of plant hybridframe material aluminumhumidity10 95%ip ratingip65operating voltage24v , ultra sonic cleaner isolated circuit design, keep water away for extra safetywide diameter transducer for best cleaning resultprofessional designpowerful transducer and clear circuttop quality steel made for body, cover and base , battery booster ac input voltage: 220v, 50hzoutput dc voltage: 1.5v upto 12voutput current: 750mastandby power: <1w , rework station ( hot air blowers for mobile ) working voltage: ac: 230 v plus or minus 10% frequency 5output power: 50 w plus or minus 10%temperature range: 200 c 480 c , pcb holder / pcb stand for mobile this is made up of a magnifying glass, double arm, set of pliers, iron stand. quality helping hands with solid heavy duty cast iron base, great for soldering and working with small items. , blade cutter cutter blade 18mmindustrial or of office usesize 150 x 17.80 x 0.40 , nose cutter type of insulation plastic insulation shape of handles bowed handle type of joint single joint15 cm , tweezers clinical purpose for picking up small objects sterile nodisposable or reusable reusableautoclavable yestype of jaws straightserrated non slip tip yeslocking of jaws noknurled non slip handle yesextra light and handy for more fatigue free working yesfirm grip yeslength of tweezer ( cm ) 15 centimetersize of jaw tips ( mm ) 3 millimetermaterial stainless steel , different types mobile opener 2 scrapers, 2 picska, 3 mini scredrivers, 1 suction cup, 1 sim eject pin , bga kit hot air heaterworking voltage: ac220 240vfrequency: 50hz / 60hzoutput power: 750wtemperature range: 100°c~480°ctemperature stability:±2?air flow: 150l / min ( max ) soldering ironworking voltage: ac220 240v output power: 80wfrequency: 50hz / 60hztemperature range: 180°c 500°ctemperature stability: ±1°csoldering iron : esd designheater material :ceramics , different types of test jig box 4 types device used to help diagnose problems in mobile phones. its main purpose is to make the phone function normally outside of its case, so we can test & check all the voltages & test points. total quantity : 1...

Surat Municipal Corporation - Gujarat

26529291 supply, erection, testing and commissioning of electrical and mechanical equipment with scopeof 03 years of operation and maintenance atparvat sps. ( 1 ) h.t vcb panel ( 2 ) airbreak switch ( 3 ) lighting arrestor ( 4 ) d.o. fuse assembly with fuse ( 5 ) pin, post insulator ( 6 ) transformer ( 7 ) ht protective relays ( 8 ) l.t power cable ( 9 ) h.t power cable ( 10 ) h.t, lt jointing kits ( 11 ) air circuit breaker ( 12 ) mccb ( 13 ) mcb, elcb, rccb ( 14 ) lt switchgears ( 15 ) soft starters ( 16 ) a.c. drives ( 17 ) electronic timers, time switch ( 18 ) manual change over switch ( 19 ) fuses ( 20 ) led indictors ( 21 ) push button ( 22 ) selector switch ( 23 ) epoxy cast resin c.t ( 24 ) electronic motor protection device ( 25 ) cable termination kit ( lugs & glands ) ( 26 ) digital meters ( 27 ) analog meters ( 28 ) apfc relays ( 29 ) capacitor ( 30 ) terminal connector ( 31 ) online ups ( 32 ) smf battery ( 33 ) engine of d.g. set ( 34 ) alternator of d.g.set ( 35 ) tools & tackels ( 36 ) test equipment ( 37 ) panel board manufacturer ( 38 ) crimping tools ( 39 ) h.t connectors ( 40 ) cable trays ( 41 ) copper / aluminum lugs ( 42 ) street light pole ( 43 ) dwc pipe ( 44 ) led ( 45 ) luminaries ( 46 ) sont lamp ( 47 ) fluorescent light fixture etc ( 48 ) electronics ballast ( 49 ) time switch ( 50 ) accessories of wiring ( 51 ) exhaust fan ( 52 ) ceiling fan ** instrumetation ( 53 ) programmable logic controllers ( plc ) ( 54 ) auxiliary control relays ( 55 ) signal ( analog ) cables ( 56 ) communication cables ( 57 ) dc power source ( 58 ) ultrasonic type level / diff. level / loh & rof / open channel flow transmitter ( 59 ) resistance temperature detector ( 60 ) pressure switch ( 61 ) float level switch ( 62 ) smoke detector ( 63 ) cctv ststem & dvr ( 64 ) differential pressure / pressure / temperature transmitter ( 65 ) temperature scanner ( 66 ) diffrential ultrasonic level transmitter ( 67 ) electromagnetic flowmeter ( full bore ) ( 68 ) water meter ( 69 ) ultrarsonic flowmeter ( 70 ) ultrasonic portable flow meters ( for pipe line ) ( 71 ) scada software ( 72 ) operator screen ( 73 ) process instruments ( 74 ) orifice plate ( 75 ) float / buoyancy switch ( 76 ) ultrasonic level transmitter / open channel flow meter ( 77 ) pressure gauge laboratory instrumenmts ( 78 ) ph / d.o. / residual chlorine analysers ( 79 ) pocket colorimeter, portable or desktop ph / turbidity / do tds / conductivity meters, data logging pre programmed spectrophotometer, analytical balance ( 80 ) toc analyser ( 81 ) recorder ( 82 ) jar test, autoclave, laboratory oven, bacteriological incubator, water still ( 83 ) auto sampler ( 84 ) computer system ( 1 ) non clog submersible pumps with guide rail, auto coupling etc. ( 2 ) horizontal non clog pumps ( 3 ) vertical non clog pumps ( 4 ) vertical turbine pumps ( 5 ) horizontal splitcase pumps ( 6 ) submersible pump ( 7 ) screw / positive displacement type pump ( 8 ) sampling pumps ( 9 ) dosing pumps ( 10 ) tube installed submersible pump ** motors ( 11 ) tefc motor for mechanical screen ( 12 ) motor ** valves, gates etc ( 13 ) knife edge gate valve ( 14 ) non return valve 15 ) non return valve ( ball type ) 16 ) sluice valve &air valves 17 ) butterfly valve 18 ) dual plate check valve 19 ) metallic expansion bellows 20 ) sluice gate 21 ) electrical actuator 22 ) s.s. elbow 23 ) c.i. fittings ** lifting equipments 24 ) electric hoist & chain pulley block 25 ) e.o.t. crane ** pneumatic system 26 ) air compressor 27 ) air filter 28 ) air filter regulator 29 ) pprc tubes 30 ) pnematic cylinders 31 ) solenoid valve 32 ) limit switches ** chlorinators ( 33 ) chlorinator ( 34 ) chlorine pressure guage ( 35 ) vacuum guage ( 36 ) chlorine booster pump ( 37 ) nrv / diaphram valve ( 38 ) interconnecting pipes ** uv disinfection ( 39 ) uv system ** pipes ( 40 ) pprc pipes ( 41 ) ss pipes ( 42 ) ms / g.i.pipes ( 43 ) d. i. pipes / c. i pipes ( 44 ) hdpe pipes ( 45 ) grp pipes ( 46 ) air diffuser ( 47 ) frp pipes & accessories ( 48 ) pvc sheets ( 49 ) paint ** other products ( 50 ) cpvc / upvc pipes ( 51 ) automatic mechanical course bar screen ( 52 ) gear box for mechanical screen &for actuator ( 53 ) process equipments ( 54 ) step type fine screen / multi rake course fine bar screen ( 55 ) moisture traps ( 56 ) centrifuge / belt filter press ( 57 ) aspirator aerators ( 58 ) archimedian screw thickener ( 59 ) surface aerators ( 60 ) bearings ( 61 ) air blowers – screw type ( 62 ) air blower centrifugal / turbo type ( 63 ) rotary air blower ( twinlobe ) / side channel type ( 64 ) agitators / stirrer mixer ( 65 ) submersible mixers for anaerobic / anoxic reactors ( 66 ) gear box ( 67 ) pressure gauge ( 68 ) frp chequered plate / gratings ( 69 ) fabrication steel plates ( 70 ) fixed film bio media ( 71 ) ro membrane ( 72 ) uf membrane ( 73 ) disk / cloth media filter ( 74 ) filter nozzels ( 75 ) tube settler ( 76 ) manual strainer ( 77 ) cartridge filter ( 78 ) activated carbon filter ( 79 ) degasser unit ( 80 ) degasser blower ** miscellaneous items ( 81 ) fasteners ( 82 ) float type flow indicator ( 83 ) refrigerator ( 84 ) air conditioners ( 85 ) hot air blower ( 86 ) membrane gas dome / holder ( 87 ) bio gas engine generator set ( 88 ) alternator ( 89 ) bio gas flaring system ( 90 ) h2s scrubber system ( 91 ) dehumidifier / chiller ( 92 ) wet ventillation system...

Western Railway - Gujarat

19246877 tender for hot air blower double insulated with cylinderical hand hold. specification as per annexure aitem list : (1) hot air blower double insulated with cylinderical hand hold.specification as per annexure asenior section gujarat 2.00 numbers...

Western Railway - Gujarat

18124316 supply of hot air blower double insulated with cylinderical hand hold. senior section gujarat 2.00 numbers...