Supply Of Surgical Items - Part 5 ( Total Part 1 To 6 ) -1597 Multiple enzymatic concentrate solution with lipases, cellulases, proteases and amylases Film based Polymer technology with controlled enzyme release Must act against all possible body secretions, compatible to all instruments Fast acting within 2- 10 minutes, allow safe disposable via the drain after use Leaves no residue after wash, Stable formulation with near neutral pH. Should have scale inhibition properties Should help retain shine of the instrument Should be usable for manual, ultra sonic and automatic cleaning systems Properties should have been tested by methods prescribed by NACE TM0374:2007 & NACE TM0169/ ASTM G31: 2012 1598 Incubator should be compatible for both Pre Vacuum and Gravity Steam Sterilizers Should have a built-in web app to allow create documentation that can be printed or saved electronically. Equipment should show remaining minutes left of BI incubation. Heating block temperature reading should be displayed Positive BI Read-out time within 1 hr by an audible alarm. Auto reader, self calibrating, to read Rapid Attest BI, with ten incubation wells Compatible BI should be FDA cleared 1599 Rapid readout biological indicators for steam sterilization containing a standardized, viable population of Bacillus stearothermophilus spores The indicator detects the presence of viable spores within 1 hour in conjunction with Super Rapid Readout Incubator Designed and certified as per ISO 11138 and EN 866. Should be compatible with the pre Vacuum cycle of 132°C to 135°C 1600 Should have a built-in web app to allow create documentation that can be printed or saved electronically. Equipment should show remaining minutes left of BI incubation. Heating block temperature reading should be displayed Positive BI Read-out time within 1 hr by an audible alarm. Auto reader, self calibrating, to read Rapid Attest BI, with ten incubation wells Compatible BI should be FDA cleared Positive BI

Tender Notice

18146311

Indian


Gujarat

November 29, 2018

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Supply Of Surgical Items - Part 5 ( Total Part 1 To 6 ) -1597 Multiple enzymatic concentrate solution with lipases, cellulases, proteases and amylases Film based Polymer technology with controlled enzyme release Must act against all possible body secretions, compatible to all instruments Fast acting within 2- 10 minutes, allow safe disposable via the drain after use Leaves no residue after wash, Stable formulation with near neutral pH. Should have scale inhibition properties Should help retain shine of the instrument Should be usable for manual, ultra sonic and automatic cleaning systems Properties should have been tested by methods prescribed by NACE TM0374:2007 & NACE TM0169/ ASTM G31: 2012 1598 Incubator should be compatible for both Pre Vacuum and Gravity Steam Sterilizers Should have a built-in web app to allow create documentation that can be printed or saved electronically. Equipment should show remaining minutes left of BI incubation. Heating block temperature reading should be displayed Positive BI Read-out time within 1 hr by an audible alarm. Auto reader, self calibrating, to read Rapid Attest BI, with ten incubation wells Compatible BI should be FDA cleared 1599 Rapid readout biological indicators for steam sterilization containing a standardized, viable population of Bacillus stearothermophilus spores The indicator detects the presence of viable spores within 1 hour in conjunction with Super Rapid Readout Incubator Designed and certified as per ISO 11138 and EN 866. Should be compatible with the pre Vacuum cycle of 132°C to 135°C 1600 Should have a built-in web app to allow create documentation that can be printed or saved electronically. Equipment should show remaining minutes left of BI incubation. Heating block temperature reading should be displayed Positive BI Read-out time within 1 hr by an audible alarm. Auto reader, self calibrating, to read Rapid Attest BI, with ten incubation wells Compatible BI should be FDA cleared Positive BI