Operation And Caretaking Of Electromechanical Services Ems At Te Building Jb Rajkot , Schedule Of Work , Operation & Caretaking Of All Electromechanical Services Including Attending Operations Involved Thereto Alongwith Arranging Necessary Tools And Safety Equipments , Maintainig Daily Record / Log-Book For Substation & A/C Plant , Dg Set Areas And All Other Duties Of Electrical Operator / Caretaking Assigned From Time To Time Complete As Per Direction Of Engineer-In-Charge . ( All Materials/Consumables Shall Be Provided By The Departement Except Distilled Water For Dg Battery ) . The Operator/ Caretaker Should Make Himself Available Within Short Time Of An Hour When Called For Any Operational Activity After His Regular Shiftt Duty . The Operator / Caretaker Shall Conduct Fire Drill Along With Jto ( E ) / Sde ( E ) & Building In-Charge Once In A Month By Testing Atleast 1/3Rd Of The Detectors At All Floors In Rotation . The Electromechanical Services Includes - ( 1 ) 2 X 500 Kva Sub Staton ( 2 ) 1 X 320 Kva & 1 X 500 Kva Dg Set ( 3 ) 5 X 7 Tr Pac Plant ( 4 ) Auto Fire Detection & Fire Alarm System Incl . 51Nos Co2 Type Fire Extinguishers ( 5 ) 2 X 3 Hp Openwell Submersible Pumps ( 6 ) 1 X 3 Hp And 1 X 1Hp Submersible Pump ( 7 ) 1 . 5/2 . 0/3 . 0 Tr Split Type A/C Units - 10Nos ( 8 ) Ei & Ei & Fans And Compound Lighting ( Note : Rate Should Be Quoted For This Item Is Rate Per Worker Per Shift ) ( Note: 1 Person Should Be Deplyoed Per Day ) ( Note : Rate Should Be Quoted For This Item Is Rate Per Worker Per Shift ) , Supplying And Fixing / Replacement Following Rating , 240V/ 415 V C Series , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning , Credit Of Faulty Item Etc . As Required . 32 A Tpn Mcb , 40 A Tpn Mcb , 5 -32 A Sp Mcb , 5 - 32 A Spn Mcb , Rewinding Of The Following Capacity Exh Fans With Copper Conductor H Class Insulated Copper Enamalled Suitable Gauge Wire I/C Taking To Workshop , Reinstallation , Painting , Servicing , Credit Of Burned Windings Etc As Reqd ( A ) Single Phase Exhaust Fans / Pedastal Fans Up To 200 Watts Cap , ( B ) Single Phase Celling Fan . , Replacement Of Existing Compound Light / Street Light Lamp On Pole/Bracket With 18 Watts Led Lamp In The Existing Fitting With Lamp Holder Etc As Reqd . , Sitc Of Aluminium Die Cast Led Street Light Fitting Of 18W Suitable For Operation On 230 V A . C . Supply I/C Removing The Existing Faulty Fitting On Pole/Bracket I/C Testing Etc . Comp . As Required . ( M/S . Syska/ Philips Of S . S . Make ) , Sitc Of 4Ft , 20W Led Type Batten Suitable For Operation On 230 V A . C . Supply I/C Removing Of Existing Faulty Fitting , Making Connection , Testing Etc . Comp . As Reqd . ( M/S . Philips Or S . S . Make ) , Supplying And Fixing Of Following Mccb/Tpn Sfu / Accesories In Existing Lt Panel I/C Dismantling Of Existing Faulty Parts , Making Connection Etc As Reqd . 63- 75 A Tp Mccb ( 25 Ka ) , 100/125 A Tp Mccb ( 35 Ka ) , 63 Amp . Tpn Sfu In Open Execution I/C Hrc Fuse Link ( Ac-23 Duty ) , 125 Amp . Tpn Sfu In Open Execution I/C Hrc Fuse Link ( Ac-23 Duty ) , 2/4 Amp Hrc Type Control Fuse Link , 63 Amp . Hrc Fuse Link . , 100/125 Amp . Hrc Fuse Link . , Replacement Of The Following Isi Marked Items I/C Credit For Non Return Of Faulty Item As Reqd . 4 Feet Long 36 Watts Flourescent Tube Rod . , 4 Feet Long 20 W / 18 W Led Tube Rods . , 230 V Starter Suitable For Flourscent Tube Rod Fitting . , Electronic Choke Suitable For Operation On Single Phase 230 Volts . , Side Holder Suitable For Flourscent Tuberod Fitting . , 5/6 Amps Capacity Piono Type Switch . , 15/16 Amps Capacity Piono Type Switch . , 5/6 Amps Capacity Modular Type Switch . , 15/16 Amps Capacity Modular Type Switch . , 5/6 Amps Capacity 3 Pin Socket Outlet . , 15/16 Amps Capacity 3 Pin Socket Outlet . , 5/6 Amps Capacity Modular Type 3 Pin Socket Outlet . , 15/16 Amps Capacity Modular Type 6 Pin Socket Outlet . , Supplying And Drawing 1X1 . 5 Sq Mm Frls Pvc Insulated Copper Conductor , Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required . , Supplying And Drawing 2X1 . 5 Sq Mm Frls Pvc Insulated Copper Conductor , Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required . , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc As Required . , 9W Led Lamp , Replacement / Supply Of Following Type Detector Complete With Base Cover / Ms Box/ Ms Round Box Of Having 4X4 / Junction Bx/ Stand / Tripod Etc And Itc Of The Same As Directed By Engineer In Charge Comp . As Reqd . Photo Electric Type Smoke Detector , Ionisation Type Smoke Detector , Replacing Of The Following Spares/ Component In Control Panel Of Existing Auto F/D System With Same Make & Model Including , Making Connections , Testing And Comissioning Etc . Comp . As Reqd . Control Card , Zone Card , Power Card , Smps Charging Unit , Replacement Of / Supply Of Manually Call Point With Led Indicator ( Pill Box ) In Ms Box Etc . Comp . As Reqd . , Refilling Of Existing 4 . 5 Kgs . Co2 Type Fire Extinguishers Including Transportation To Authorised Service Centre Including Testing , Pvdg . Data Sheet Sticker & Factory Certificate Etc As Required , Replacement Of Defective 1 . 0 Mtr Long Hose Pipe ( Steel Wire Breaded Pipe ) With Brand New Pressure Tested Horn Pipe A/W Suitable For Existing 4 . 5/3 . 6 Kg Co2 Type Fire Extinguishers Etc As Required . , Replacement / Supply Of Following Rating Sealed Maintenance Free Battery In Dully Charged Condition I/C Fixing Making Connection Testing Etc . As Required ( Approved Make Of Bsnl ) 12 Volts , 20 Ah

Tender Notice

25815438

Bharat Sanchar Nigam Limited

Indian


Gujarat

November 06, 2020

Key Value

2.41 Lakhs

2.41 Lakhs

2.41 Lakhs

To Download Tender Document Click on the below link

Operation And Caretaking Of Electromechanical Services Ems At Te Building Jb Rajkot , Schedule Of Work , Operation & Caretaking Of All Electromechanical Services Including Attending Operations Involved Thereto Alongwith Arranging Necessary Tools And Safety Equipments , Maintainig Daily Record / Log-Book For Substation & A/C Plant , Dg Set Areas And All Other Duties Of Electrical Operator / Caretaking Assigned From Time To Time Complete As Per Direction Of Engineer-In-Charge . ( All Materials/Consumables Shall Be Provided By The Departement Except Distilled Water For Dg Battery ) . The Operator/ Caretaker Should Make Himself Available Within Short Time Of An Hour When Called For Any Operational Activity After His Regular Shiftt Duty . The Operator / Caretaker Shall Conduct Fire Drill Along With Jto ( E ) / Sde ( E ) & Building In-Charge Once In A Month By Testing Atleast 1/3Rd Of The Detectors At All Floors In Rotation . The Electromechanical Services Includes - ( 1 ) 2 X 500 Kva Sub Staton ( 2 ) 1 X 320 Kva & 1 X 500 Kva Dg Set ( 3 ) 5 X 7 Tr Pac Plant ( 4 ) Auto Fire Detection & Fire Alarm System Incl . 51Nos Co2 Type Fire Extinguishers ( 5 ) 2 X 3 Hp Openwell Submersible Pumps ( 6 ) 1 X 3 Hp And 1 X 1Hp Submersible Pump ( 7 ) 1 . 5/2 . 0/3 . 0 Tr Split Type A/C Units - 10Nos ( 8 ) Ei & Ei & Fans And Compound Lighting ( Note : Rate Should Be Quoted For This Item Is Rate Per Worker Per Shift ) ( Note: 1 Person Should Be Deplyoed Per Day ) ( Note : Rate Should Be Quoted For This Item Is Rate Per Worker Per Shift ) , Supplying And Fixing / Replacement Following Rating , 240V/ 415 V C Series , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning , Credit Of Faulty Item Etc . As Required . 32 A Tpn Mcb , 40 A Tpn Mcb , 5 -32 A Sp Mcb , 5 - 32 A Spn Mcb , Rewinding Of The Following Capacity Exh Fans With Copper Conductor H Class Insulated Copper Enamalled Suitable Gauge Wire I/C Taking To Workshop , Reinstallation , Painting , Servicing , Credit Of Burned Windings Etc As Reqd ( A ) Single Phase Exhaust Fans / Pedastal Fans Up To 200 Watts Cap , ( B ) Single Phase Celling Fan . , Replacement Of Existing Compound Light / Street Light Lamp On Pole/Bracket With 18 Watts Led Lamp In The Existing Fitting With Lamp Holder Etc As Reqd . , Sitc Of Aluminium Die Cast Led Street Light Fitting Of 18W Suitable For Operation On 230 V A . C . Supply I/C Removing The Existing Faulty Fitting On Pole/Bracket I/C Testing Etc . Comp . As Required . ( M/S . Syska/ Philips Of S . S . Make ) , Sitc Of 4Ft , 20W Led Type Batten Suitable For Operation On 230 V A . C . Supply I/C Removing Of Existing Faulty Fitting , Making Connection , Testing Etc . Comp . As Reqd . ( M/S . Philips Or S . S . Make ) , Supplying And Fixing Of Following Mccb/Tpn Sfu / Accesories In Existing Lt Panel I/C Dismantling Of Existing Faulty Parts , Making Connection Etc As Reqd . 63- 75 A Tp Mccb ( 25 Ka ) , 100/125 A Tp Mccb ( 35 Ka ) , 63 Amp . Tpn Sfu In Open Execution I/C Hrc Fuse Link ( Ac-23 Duty ) , 125 Amp . Tpn Sfu In Open Execution I/C Hrc Fuse Link ( Ac-23 Duty ) , 2/4 Amp Hrc Type Control Fuse Link , 63 Amp . Hrc Fuse Link . , 100/125 Amp . Hrc Fuse Link . , Replacement Of The Following Isi Marked Items I/C Credit For Non Return Of Faulty Item As Reqd . 4 Feet Long 36 Watts Flourescent Tube Rod . , 4 Feet Long 20 W / 18 W Led Tube Rods . , 230 V Starter Suitable For Flourscent Tube Rod Fitting . , Electronic Choke Suitable For Operation On Single Phase 230 Volts . , Side Holder Suitable For Flourscent Tuberod Fitting . , 5/6 Amps Capacity Piono Type Switch . , 15/16 Amps Capacity Piono Type Switch . , 5/6 Amps Capacity Modular Type Switch . , 15/16 Amps Capacity Modular Type Switch . , 5/6 Amps Capacity 3 Pin Socket Outlet . , 15/16 Amps Capacity 3 Pin Socket Outlet . , 5/6 Amps Capacity Modular Type 3 Pin Socket Outlet . , 15/16 Amps Capacity Modular Type 6 Pin Socket Outlet . , Supplying And Drawing 1X1 . 5 Sq Mm Frls Pvc Insulated Copper Conductor , Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required . , Supplying And Drawing 2X1 . 5 Sq Mm Frls Pvc Insulated Copper Conductor , Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required . , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc As Required . , 9W Led Lamp , Replacement / Supply Of Following Type Detector Complete With Base Cover / Ms Box/ Ms Round Box Of Having 4X4 / Junction Bx/ Stand / Tripod Etc And Itc Of The Same As Directed By Engineer In Charge Comp . As Reqd . Photo Electric Type Smoke Detector , Ionisation Type Smoke Detector , Replacing Of The Following Spares/ Component In Control Panel Of Existing Auto F/D System With Same Make & Model Including , Making Connections , Testing And Comissioning Etc . Comp . As Reqd . Control Card , Zone Card , Power Card , Smps Charging Unit , Replacement Of / Supply Of Manually Call Point With Led Indicator ( Pill Box ) In Ms Box Etc . Comp . As Reqd . , Refilling Of Existing 4 . 5 Kgs . Co2 Type Fire Extinguishers Including Transportation To Authorised Service Centre Including Testing , Pvdg . Data Sheet Sticker & Factory Certificate Etc As Required , Replacement Of Defective 1 . 0 Mtr Long Hose Pipe ( Steel Wire Breaded Pipe ) With Brand New Pressure Tested Horn Pipe A/W Suitable For Existing 4 . 5/3 . 6 Kg Co2 Type Fire Extinguishers Etc As Required . , Replacement / Supply Of Following Rating Sealed Maintenance Free Battery In Dully Charged Condition I/C Fixing Making Connection Testing Etc . As Required ( Approved Make Of Bsnl ) 12 Volts , 20 Ah