Pre Bid Tie Up With The Gis Manufacturer For Supply And Services Of 400 Kv Gis For Powergrid Khavada-1 ( Kps1 ) Pre Bid Tie Up With The Gis Manufacturer For Supply And Services Of 400 Kv Gis For Powergrid Khavada-1 ( Kps1 , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Bus Reactor Feeder Bay , Supply- Gis : 400Kv, 63Ka For 1S, 4000A Gis Bus Bar Module , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Tie Bay Without Pir , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Ict Feeder Bay , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Line Feeder Bay Without Pir , Supply- Gis : 400Kv, Gis Bus Sectionaliser Module , Supply- Gis : 420Kv, 63Ka For 1S, 3150A, Sf6 Gis Auxiliary Bus Module For Spare Transformer , Supply- Gis : 400Kv, 63Ka For 1S, 3000A, Single Phase Gas Insulated Bus Duct Outside Gis Hall , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Single Phase Sf6 To Air Bushing , Supply- Gis : 400Kv, Controlled Switching Device ( Csd ) For Gis 3-Ph Circuit Breaker , Supply- Gis : Sf6 Gas Required For Placing Gis Into Successful Operation , Supply- Gis : Structure Material Including Foundation Bolts, Embedded Items, Rails And / Or Other Materials Etc. , Supply- Gis :Earthing Materials Including High Frequency Earthing ( As Applicable ) , Supply- Gis : Tools And Tackles , 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch / Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets, O-Ringsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags ( 5 % Of Totalweight ) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type ( Complete With Metal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis- 3150A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, Mcb, Fuses, Timers, Terminal Blocks Etc. Of Each Type & Rating-400Kv Gis , 400Kv Gis-One Pole Of 3150A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 3150A Circuit Breaker With Pir With Interrupter, Main Circuit, Enclosure And Operating Mechanism Complete In All Respect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker ( As Applicable ) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker ( As Applicable ) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. ( Asapplicable ) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor ( For Hydraulic Operated Mechanism, If Applicable ) , Hydraulic Filter Of Each Type ( For Hydraulic Operated Mechanism, Ifpplicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type ( As Applicable ) ( Forhydraulic Operated Mechanism, If Applicable ) , 400Kv Gis Circuit Breaker - N2 Accumulator ( For Hydraulic Operatedmechanism, If Applicable ) , Valves Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pipe Length ( Copper & Steel ) Of Each Size & Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil ( 5% Of Total Oil Quantity ) ( For Hydraulic Operated Mechanism, If Applicable ) , Pressure Relief Device Of Each Type ( For Hydraulic Operated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. ( For Spring Operated Mechanism, Ifapplicable ) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. ( For Hydraulic-Springoperated Mechanism, If Applicable ) , Pressure Switches Of Each Type For420kv Giscircuit Breaker ( Forhydraulic-Spring Operated Mechanism, Ifapplicable ) , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulic-Springoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis- Single Phase Of 3150Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect ( Please Refer Additional Notes In Remark Column ) , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect ( Please Refer Additional Notes In Remark Column ) , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch ( If Applicable ) -400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer ( 3 Cores, Type-Cta ) With Associated Enclosure And Primary Conductor Complete In All Respect , 400Kv Gis- Single Phase Of Current Transformer ( 2 Cores, Type-Ctb ) With Associated Enclosure And Primary Conductor Complete In All Respect , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In All Respect , Services- Gis : 400Kv, Supervision Of Erection Of Gis , Services- Gis : 400Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 400Kv, Supervision Of Erection Of Csd Complete In All Respect , Services- Gis : 400Kv, Testing & Commissioning Of Gis , Services- Gis : 400Kv, Testing & Commissioning Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Testing & Commissioning Of Sf6 To Air Bushing , Services- Gis : 400Kv, Testing & Commissioning Of Csd , Services- Gis : 400Kv, Final Successful Hv / Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- Gis : Insulation Co-Ordination Studies For Gis System , Reference Unit Pricespares- Gis : 400Kv, 63Ka For 1S, 4000A, Single Phase Bus Bar , Reference Unit Pricespares- Gis : 400Kv, Gis Metallic Enclosure , Reference Unit Pricespares- Gis : 400Kv, Expansion Bellows / Joints , Reference Unit Pricespares- Gis : 400Kv, Tee Bend , Reference Unit Pricespares- Gis : 400Kv, Angle Bend ( 135° ) , Reference Unit Pricespares- Gis : 400Kv, L-Bend , Reference Unit Priceservices- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Services For Supervision Of Erection Of Gis , Reference Unit Priceservices- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Services For Testing & Commissioning Of Gis , Reference Unit Priceservices- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Hiring Charges Of Hv Test Kit With Operator , Reference Unit Priceservices- Gis : Training For Gis At Site , Reference Unit Priceservices- Gis : Training For Gis At Manufacturer Works

Tender Notice

31263956

Indian


Gujarat

November 23, 2022

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Pre Bid Tie Up With The Gis Manufacturer For Supply And Services Of 400 Kv Gis For Powergrid Khavada-1 ( Kps1 ) Pre Bid Tie Up With The Gis Manufacturer For Supply And Services Of 400 Kv Gis For Powergrid Khavada-1 ( Kps1 , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Bus Reactor Feeder Bay , Supply- Gis : 400Kv, 63Ka For 1S, 4000A Gis Bus Bar Module , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Tie Bay Without Pir , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Ict Feeder Bay , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Line Feeder Bay Without Pir , Supply- Gis : 400Kv, Gis Bus Sectionaliser Module , Supply- Gis : 420Kv, 63Ka For 1S, 3150A, Sf6 Gis Auxiliary Bus Module For Spare Transformer , Supply- Gis : 400Kv, 63Ka For 1S, 3000A, Single Phase Gas Insulated Bus Duct Outside Gis Hall , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Single Phase Sf6 To Air Bushing , Supply- Gis : 400Kv, Controlled Switching Device ( Csd ) For Gis 3-Ph Circuit Breaker , Supply- Gis : Sf6 Gas Required For Placing Gis Into Successful Operation , Supply- Gis : Structure Material Including Foundation Bolts, Embedded Items, Rails And / Or Other Materials Etc. , Supply- Gis :Earthing Materials Including High Frequency Earthing ( As Applicable ) , Supply- Gis : Tools And Tackles , 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch / Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets, O-Ringsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags ( 5 % Of Totalweight ) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type ( Complete With Metal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis- 3150A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, Mcb, Fuses, Timers, Terminal Blocks Etc. Of Each Type & Rating-400Kv Gis , 400Kv Gis-One Pole Of 3150A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 3150A Circuit Breaker With Pir With Interrupter, Main Circuit, Enclosure And Operating Mechanism Complete In All Respect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker ( As Applicable ) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker ( As Applicable ) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. ( Asapplicable ) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor ( For Hydraulic Operated Mechanism, If Applicable ) , Hydraulic Filter Of Each Type ( For Hydraulic Operated Mechanism, Ifpplicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type ( As Applicable ) ( Forhydraulic Operated Mechanism, If Applicable ) , 400Kv Gis Circuit Breaker - N2 Accumulator ( For Hydraulic Operatedmechanism, If Applicable ) , Valves Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pipe Length ( Copper & Steel ) Of Each Size & Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil ( 5% Of Total Oil Quantity ) ( For Hydraulic Operated Mechanism, If Applicable ) , Pressure Relief Device Of Each Type ( For Hydraulic Operated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. ( For Spring Operated Mechanism, Ifapplicable ) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. ( For Hydraulic-Springoperated Mechanism, If Applicable ) , Pressure Switches Of Each Type For420kv Giscircuit Breaker ( Forhydraulic-Spring Operated Mechanism, Ifapplicable ) , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulic-Springoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis- Single Phase Of 3150Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect ( Please Refer Additional Notes In Remark Column ) , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect ( Please Refer Additional Notes In Remark Column ) , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch ( If Applicable ) -400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer ( 3 Cores, Type-Cta ) With Associated Enclosure And Primary Conductor Complete In All Respect , 400Kv Gis- Single Phase Of Current Transformer ( 2 Cores, Type-Ctb ) With Associated Enclosure And Primary Conductor Complete In All Respect , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In All Respect , Services- Gis : 400Kv, Supervision Of Erection Of Gis , Services- Gis : 400Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 400Kv, Supervision Of Erection Of Csd Complete In All Respect , Services- Gis : 400Kv, Testing & Commissioning Of Gis , Services- Gis : 400Kv, Testing & Commissioning Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Testing & Commissioning Of Sf6 To Air Bushing , Services- Gis : 400Kv, Testing & Commissioning Of Csd , Services- Gis : 400Kv, Final Successful Hv / Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- Gis : Insulation Co-Ordination Studies For Gis System , Reference Unit Pricespares- Gis : 400Kv, 63Ka For 1S, 4000A, Single Phase Bus Bar , Reference Unit Pricespares- Gis : 400Kv, Gis Metallic Enclosure , Reference Unit Pricespares- Gis : 400Kv, Expansion Bellows / Joints , Reference Unit Pricespares- Gis : 400Kv, Tee Bend , Reference Unit Pricespares- Gis : 400Kv, Angle Bend ( 135° ) , Reference Unit Pricespares- Gis : 400Kv, L-Bend , Reference Unit Priceservices- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Services For Supervision Of Erection Of Gis , Reference Unit Priceservices- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Services For Testing & Commissioning Of Gis , Reference Unit Priceservices- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Hiring Charges Of Hv Test Kit With Operator , Reference Unit Priceservices- Gis : Training For Gis At Site , Reference Unit Priceservices- Gis : Training For Gis At Manufacturer Works