Quotation For Repairing/Replacement Of Parts Of Of Various Instruments Of Pediatric Department ,Smimer Hospital -1. Bilirubin Meter Make: Draeger Model: JM- 105 (A) Specification For battery  Ni-Mh Battery, 2.4v 600mAH  The compatible battery should be compatible with the above specified unit & its battery space  Bidders can visit and take a complete overview of the battery before quoting.  ISO/BIS/CE/CDSCO certified product with safety certificates if any. 6 month Warranty 2. Radiant Warmer Model: nice 2007 Make : Nice Neotech Medical Systems Pvt. Ltd. Sr.NO.IRW220201042, IRW220201048 (A) Specification For skin probe & Observation Lamp:-  The skin probe must be compatible with the above mentioned radiant warmer unit.  Should be highly accurate sensor with accuracy of ±0.2 oC.  Sensor tip with broad surface.  Long length cable to reach the infant from the warmer.  Easy to plug in/out male connector  Should be a biocompatible material in order to ensure the baby is free from skin irritation.  Should be ISO/CE/BIS/CDSCO certified product.  Bidders are requested to kindly visit the site for a complete overview of thw product One year Comprehensive Warranty. 3. Bubble CPAP without compressor. Make:Viasys Healthcare Model: Bird (A) Specification For Compitable Low flow Low flow air oxygen blender  Low flow air oxygen blender should provide mixed gas of up to 30 LPM  Combine compressed Medical Air and Oxygen to deliver blended pressurized gas at aprecise oxygen concentration(FiO2) when set by the user.  Highly accurate delivery of FiO2 with knob adjustment from 21 to 100%  Should be ideal for equipment requirng 2- 30 LPM.  Should have Non-interchangeable input port for air and oxygen.  Primary and auxiliary flow meter provisions provided.  bleed ON/OFF should be there for more accuracy during low output flow.  Highly audible pneumatic alarm when input pressure differentiates between 20±2 psi.  Rigid aluminum body or better and highly precise mechanical components ensures the accurate mixture of input gases.  The blender should be easily calibrated whenever required by the user.  These blenders are suitable for respiratory applications like Bubble CPAP mainly for critically-limited NICU procedures.  Should be provide with graduated O2 flow meter.  The bidders can visit the site for a complete overview of the product before bidding .  Certificates:-Particular Safety Standard(Blender)-ISO 11195& QMS-ISO 13485 One year Comprehensive Warranty

Tender Notice

37551533

Surat Municipal Corporation

Indian


Surat

Gujarat

May 10, 2023

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Quotation For Repairing/Replacement Of Parts Of Of Various Instruments Of Pediatric Department ,Smimer Hospital -1. Bilirubin Meter Make: Draeger Model: JM- 105 (A) Specification For battery  Ni-Mh Battery, 2.4v 600mAH  The compatible battery should be compatible with the above specified unit & its battery space  Bidders can visit and take a complete overview of the battery before quoting.  ISO/BIS/CE/CDSCO certified product with safety certificates if any. 6 month Warranty 2. Radiant Warmer Model: nice 2007 Make : Nice Neotech Medical Systems Pvt. Ltd. Sr.NO.IRW220201042, IRW220201048 (A) Specification For skin probe & Observation Lamp:-  The skin probe must be compatible with the above mentioned radiant warmer unit.  Should be highly accurate sensor with accuracy of ±0.2 oC.  Sensor tip with broad surface.  Long length cable to reach the infant from the warmer.  Easy to plug in/out male connector  Should be a biocompatible material in order to ensure the baby is free from skin irritation.  Should be ISO/CE/BIS/CDSCO certified product.  Bidders are requested to kindly visit the site for a complete overview of thw product One year Comprehensive Warranty. 3. Bubble CPAP without compressor. Make:Viasys Healthcare Model: Bird (A) Specification For Compitable Low flow Low flow air oxygen blender  Low flow air oxygen blender should provide mixed gas of up to 30 LPM  Combine compressed Medical Air and Oxygen to deliver blended pressurized gas at aprecise oxygen concentration(FiO2) when set by the user.  Highly accurate delivery of FiO2 with knob adjustment from 21 to 100%  Should be ideal for equipment requirng 2- 30 LPM.  Should have Non-interchangeable input port for air and oxygen.  Primary and auxiliary flow meter provisions provided.  bleed ON/OFF should be there for more accuracy during low output flow.  Highly audible pneumatic alarm when input pressure differentiates between 20±2 psi.  Rigid aluminum body or better and highly precise mechanical components ensures the accurate mixture of input gases.  The blender should be easily calibrated whenever required by the user.  These blenders are suitable for respiratory applications like Bubble CPAP mainly for critically-limited NICU procedures.  Should be provide with graduated O2 flow meter.  The bidders can visit the site for a complete overview of the product before bidding .  Certificates:-Particular Safety Standard(Blender)-ISO 11195& QMS-ISO 13485 One year Comprehensive Warranty