Expression Of Interest [Eoi] For Electrification Of The Dome Shaped Storage Sheds Inside Cargo Jetty Area -1 Supply at site 4 Core, 150 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 1 2 Supply at site 4 Core, 70 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 2 3 Supply at site 4 Core, 35 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 3 4 Supply at site 4 Core, 6 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 4 5 Supply at site 3 core, 1.5 Sq.mm, 1.1kV grade, armoured Copper conductor XLPE cable as per Technical Specification No. 5 6 Supply at site 400mm width hot dip galvanized ladder type cable tray along with its accessories as per Technical Specification No. 6 7 Supply at site 300mm width hot dip galvanized ladder type cable tray along with its accessories as per Technical Specification No. 7 8 Supply at site 200mm width hot dip galvanized ladder type cable tray along with its accessories as per Technical Specification No. 8 9 Supply at site of 400mm width hot dip galvanized 90 degree Bend as per Technical Specification No. 9 10 Supply at site 300mm width hot dip galvanized Vertical Inside Riser as per Technical Specification No. 10 11 Supply at site 300mm width hot dip galvanized Vertical Outside Riser as per Technical Specification No. 11 12 Supply at site hot dip galvanized Right hand Reducer of size 400mm to 300mm width as per Technical Specification No. 12 13 Supply at site hot dip galvanized Left hand Reducer of size 400mm to 300mm width as per Technical Specification No. 13 14 Supply at site 600mm Cantilever Bracket for cable tray as per Technical Specification No. 14 15 Supply at site 500mm Cantilever Bracket for cable tray as per Technical Specification No. 15 16 Supply at site 400mm Cantilever Bracket for cable tray as per Technical Specification No. 16 17 Supply at site 500mm Pipe Bracket for cable tray as per Technical Specification No. 17 18 Supply at site 400mm Pipe Bracket for cable tray as per Technical Specification No. 18 19 Supply at site 300mm Stand-off Bracket for cable tray as per Technical Specification No. 19 20 Supply at site J – Hanger & Bracket Clamp as per Technical Specification No. 20 21 Fixing of 600mm Cantilever Bracket as per Technical Specification No. 21 22 Fixing of 500mm Cantilever Bracket as per Technical Specification No. 22 23 Fixing of 400mm Cantilever Bracket as per Technical Specification No. 23 24 Fixing of 500mm Pipe Bracket as per Technical Specification No. 24 25 Fixing of 400mm Pipe Bracket as per Technical Specification No. 25 26 Fixing of 300mm Stand-off Bracket as per Technical Specification No. 26 27 Fixing of 300mm Stand-off Bracket as per Technical Specification No. 27 28 Fixing of 400mm width hot dip galvanized ladder type cable tray along with its accessories on cantilever bracket as per Technical Specification No. 28 29 Fixing of 400mm width hot dip galvanized ladder type cable tray along with its accessories on bracket as per Technical Specification No. 29 30 Fixing of 300mm width hot dip galvanized Vertical Inside Riser as per Technical Specification No. 30 31 Fixing of 300mm width hot dip galvanized Vertical Outside Riser as per Technical Specification No. 31 32 Fixing of 300mm width hot dip galvanized ladder type cable tray along with its accessories on cantilever bracket as per Technical Specification No. 32 33 Fixing of 300mm width hot dip galvanized ladder type cable tray along with its accessories on bracket as per Technical Specification No. 33 34 Fixing of 200mm width hot dip galvanized ladder type cable tray along with its accessories on cantilever bracket as per Technical Specification No. 34 35 Fixing of 200mm width hot dip galvanized ladder type cable tray along with its accessories on bracket as per Technical Specification No. 35 36 Fixing of 400mm width hot dip galvanized 90 degree Bend as per Technical Specification No. 36 37 Fixing of hot dip galvanized Right hand Reducer of size 400mm to 300mm width as per Technical Specification No. 37 38 Fixing of hot dip galvanized Left hand Reducer of size 400mm to 300mm width as per Technical Specification No. 38 39 Fixing of J – Hanger & Bracket Clamp as per Technical Specification No. 39 40 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Existing Trench of Substation as per Technical Specification No. 40 41 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through existing NP2 Pipe as per Technical Specification No. 41 42 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Existing RCC Trench as per Technical Specification No. 42 43 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 43 44 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 44 45 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 45 46 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Existing Trench of Substation as per Technical Specification No. 46 47 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through J – hanger as per Technical Specification No. 47 48 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable on Vertical Tray as per Technical Specification No. 48 49 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Road/Railway Crossing by HDD method as per Technical Specification No. 49 50 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 50 51 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 51 52 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 52 53 Laying of 1.1kV 4 Core 70 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 53 54 Laying of 1.1kV 4 Core 70 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 54 55 Laying of 1.1kV 4 Core 70 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 55 56 Laying of 1.1kV 4 Core 35 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 56 57 Laying of 1.1kV 4 Core 35 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 57 58 Laying of 1.1kV 4 Core 35 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 58 59 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 59 60 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 60 61 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Clamping on RCC Structure as per Technical Specification No. 61 62 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 62 63 Laying of 3 core, 1.5 Sq.mm, 1.1kV grade LT armoured Copper conductor XLPE cable on RCC Structure through clamps as per Technical Specification No. 63 64 Laying of 3 core, 1.5 Sq.mm, 1.1kV grade LT armoured Copper conductor XLPE cable through existing hangers provided in dome shaped roof structure as per Technical Specification No. 64 65 Laying of 3 core, 1.5 Sq.mm, 1.1kV grade LT armoured Copper conductor XLPE cable as Loop as per Technical Specification No. 65 66 Supply at site LT Load Point Panel as per Technical Specification No. 66 67 Supply at site LT Sub Load Point Panel as per Technical Specification No. 67 68 Supply at site FRP 8-Way Power Distribution Board as per Technical Specification No. 68 69 Installation, Testing & Commissioning of LT Load Point Panel as per Technical Specification No. 69 70 Installation, Testing & Commissioning of LT Sub Load Point Panel as per Technical Specification No. 70 71 Installation, Testing & Commissioning of FRP 8-Way Power Distribution Board as per Technical Specification No. 71 72 Supply at site FRP Junction Box as per Technical Specification No. 72 73 Fixing of FRP Junction Box as per Technical Specification No. 73 74 Supply at site LED High Bay fitting for inside Shed Area as per Technical Specification No. 74 75 Installation, Testing & Commissioning of LED High Bay fitting as per Technical Specification No. 75 76 Supply at site LED Flood Light fitting as per Technical Specification No. 76 77 Installation, Testing & Commissioning of LED Flood Light fitting as per Technical Specification No. 77 78 Preparation of earthing system with 60mm diameter, 3m GI electrode & chemical back fill compound as per Technical Specification No. 78 79 Supply, Laying, connecting of GI Strip of 50×6 mm size between earth station to the equipment as per Technical Specification No. 79 80 Supply, Laying, connecting of GI Strip of 25×6 mm size as per Technical Specification No. 80 81 Supply, Laying, connecting of GI Wire of 8 SWG size as per Technical Specification No. 81

Tender Notice

43310876

deendayal port trust

Indian


KUTCH

Gujarat

May 13, 2024

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Expression Of Interest [Eoi] For Electrification Of The Dome Shaped Storage Sheds Inside Cargo Jetty Area -1 Supply at site 4 Core, 150 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 1 2 Supply at site 4 Core, 70 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 2 3 Supply at site 4 Core, 35 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 3 4 Supply at site 4 Core, 6 Sq.mm, 1.1kV grade, armoured aluminium conductor XLPE cable as per Technical Specification No. 4 5 Supply at site 3 core, 1.5 Sq.mm, 1.1kV grade, armoured Copper conductor XLPE cable as per Technical Specification No. 5 6 Supply at site 400mm width hot dip galvanized ladder type cable tray along with its accessories as per Technical Specification No. 6 7 Supply at site 300mm width hot dip galvanized ladder type cable tray along with its accessories as per Technical Specification No. 7 8 Supply at site 200mm width hot dip galvanized ladder type cable tray along with its accessories as per Technical Specification No. 8 9 Supply at site of 400mm width hot dip galvanized 90 degree Bend as per Technical Specification No. 9 10 Supply at site 300mm width hot dip galvanized Vertical Inside Riser as per Technical Specification No. 10 11 Supply at site 300mm width hot dip galvanized Vertical Outside Riser as per Technical Specification No. 11 12 Supply at site hot dip galvanized Right hand Reducer of size 400mm to 300mm width as per Technical Specification No. 12 13 Supply at site hot dip galvanized Left hand Reducer of size 400mm to 300mm width as per Technical Specification No. 13 14 Supply at site 600mm Cantilever Bracket for cable tray as per Technical Specification No. 14 15 Supply at site 500mm Cantilever Bracket for cable tray as per Technical Specification No. 15 16 Supply at site 400mm Cantilever Bracket for cable tray as per Technical Specification No. 16 17 Supply at site 500mm Pipe Bracket for cable tray as per Technical Specification No. 17 18 Supply at site 400mm Pipe Bracket for cable tray as per Technical Specification No. 18 19 Supply at site 300mm Stand-off Bracket for cable tray as per Technical Specification No. 19 20 Supply at site J – Hanger & Bracket Clamp as per Technical Specification No. 20 21 Fixing of 600mm Cantilever Bracket as per Technical Specification No. 21 22 Fixing of 500mm Cantilever Bracket as per Technical Specification No. 22 23 Fixing of 400mm Cantilever Bracket as per Technical Specification No. 23 24 Fixing of 500mm Pipe Bracket as per Technical Specification No. 24 25 Fixing of 400mm Pipe Bracket as per Technical Specification No. 25 26 Fixing of 300mm Stand-off Bracket as per Technical Specification No. 26 27 Fixing of 300mm Stand-off Bracket as per Technical Specification No. 27 28 Fixing of 400mm width hot dip galvanized ladder type cable tray along with its accessories on cantilever bracket as per Technical Specification No. 28 29 Fixing of 400mm width hot dip galvanized ladder type cable tray along with its accessories on bracket as per Technical Specification No. 29 30 Fixing of 300mm width hot dip galvanized Vertical Inside Riser as per Technical Specification No. 30 31 Fixing of 300mm width hot dip galvanized Vertical Outside Riser as per Technical Specification No. 31 32 Fixing of 300mm width hot dip galvanized ladder type cable tray along with its accessories on cantilever bracket as per Technical Specification No. 32 33 Fixing of 300mm width hot dip galvanized ladder type cable tray along with its accessories on bracket as per Technical Specification No. 33 34 Fixing of 200mm width hot dip galvanized ladder type cable tray along with its accessories on cantilever bracket as per Technical Specification No. 34 35 Fixing of 200mm width hot dip galvanized ladder type cable tray along with its accessories on bracket as per Technical Specification No. 35 36 Fixing of 400mm width hot dip galvanized 90 degree Bend as per Technical Specification No. 36 37 Fixing of hot dip galvanized Right hand Reducer of size 400mm to 300mm width as per Technical Specification No. 37 38 Fixing of hot dip galvanized Left hand Reducer of size 400mm to 300mm width as per Technical Specification No. 38 39 Fixing of J – Hanger & Bracket Clamp as per Technical Specification No. 39 40 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Existing Trench of Substation as per Technical Specification No. 40 41 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through existing NP2 Pipe as per Technical Specification No. 41 42 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Existing RCC Trench as per Technical Specification No. 42 43 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 43 44 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 44 45 Laying of double run of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 45 46 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Existing Trench of Substation as per Technical Specification No. 46 47 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through J – hanger as per Technical Specification No. 47 48 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable on Vertical Tray as per Technical Specification No. 48 49 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Road/Railway Crossing by HDD method as per Technical Specification No. 49 50 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 50 51 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 51 52 Laying of 1.1kV 4 Core 150 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 52 53 Laying of 1.1kV 4 Core 70 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 53 54 Laying of 1.1kV 4 Core 70 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 54 55 Laying of 1.1kV 4 Core 70 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 55 56 Laying of 1.1kV 4 Core 35 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 56 57 Laying of 1.1kV 4 Core 35 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 57 58 Laying of 1.1kV 4 Core 35 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 58 59 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Cable Tray as per Technical Specification No. 59 60 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable in Vertical Cable Tray as per Technical Specification No. 60 61 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable through Clamping on RCC Structure as per Technical Specification No. 61 62 Laying of 1.1kV 4 Core 6 Sq.mm Aluminium Conductor XLPE Insulated Armoured Cable as Loop as per Technical Specification No. 62 63 Laying of 3 core, 1.5 Sq.mm, 1.1kV grade LT armoured Copper conductor XLPE cable on RCC Structure through clamps as per Technical Specification No. 63 64 Laying of 3 core, 1.5 Sq.mm, 1.1kV grade LT armoured Copper conductor XLPE cable through existing hangers provided in dome shaped roof structure as per Technical Specification No. 64 65 Laying of 3 core, 1.5 Sq.mm, 1.1kV grade LT armoured Copper conductor XLPE cable as Loop as per Technical Specification No. 65 66 Supply at site LT Load Point Panel as per Technical Specification No. 66 67 Supply at site LT Sub Load Point Panel as per Technical Specification No. 67 68 Supply at site FRP 8-Way Power Distribution Board as per Technical Specification No. 68 69 Installation, Testing & Commissioning of LT Load Point Panel as per Technical Specification No. 69 70 Installation, Testing & Commissioning of LT Sub Load Point Panel as per Technical Specification No. 70 71 Installation, Testing & Commissioning of FRP 8-Way Power Distribution Board as per Technical Specification No. 71 72 Supply at site FRP Junction Box as per Technical Specification No. 72 73 Fixing of FRP Junction Box as per Technical Specification No. 73 74 Supply at site LED High Bay fitting for inside Shed Area as per Technical Specification No. 74 75 Installation, Testing & Commissioning of LED High Bay fitting as per Technical Specification No. 75 76 Supply at site LED Flood Light fitting as per Technical Specification No. 76 77 Installation, Testing & Commissioning of LED Flood Light fitting as per Technical Specification No. 77 78 Preparation of earthing system with 60mm diameter, 3m GI electrode & chemical back fill compound as per Technical Specification No. 78 79 Supply, Laying, connecting of GI Strip of 50×6 mm size between earth station to the equipment as per Technical Specification No. 79 80 Supply, Laying, connecting of GI Strip of 25×6 mm size as per Technical Specification No. 80 81 Supply, Laying, connecting of GI Wire of 8 SWG size as per Technical Specification No. 81