Tender For Structure And Piping Corrosion - Hsm Plant 48010 10 10 10 Surface Preparation to ST-2 standard & 8,000 M2 20 SUPPLY&APPLY OF EPOXY HB AL PRIMER 8,000 M2 30 SUPPLY&APPLY EPOXY HB MIO 8,000 M2 40 SUPPLY&APPLY PU HB TOPCOAT 8,000 M2 50 SCAFFOLDING WITH MATERIAL ABOVE 20 MTR 6,968 M3 Email : SANJAY.SHIROYA@AMNS.IN Contact : Name : Sanjay Shiroya Item Details : SPR FOR HSM STRUCTURE AND PIPING CORROSION PROTECTION PAINTING-CY-2023. Scope of Work- Vendor SURFACE PREPARATION & PRIMARING & PAINTING. PAINTING OF BASEMENT STRUCTURE AND PIPING. PAINTING OF 15 COLUMNS IN HSM SHADE. PAINTING OF CRANE MAINTENANCE STRUCTURE. PAINTING OF NG PIPELINE ALL WORK AND SCOPE WILL BE AS PER ATTACHED DOCUMENTS. ALL PAINTING MATERIALS ARE IN VENDOR SCOPE. PAINT MAKE - NEROLAC / MORSAN OR EQUIVALENT. QUALITY CERTIFICATE BY NACE CERTIFIED ENGINEER. SCAFFOLDING - WHEREVER REQUIRED TAKE CARE BY VENDOR. AMNS STANDARD COATING AS WELL AS WORK DOCUMENTS ARE ATTACHED HEREWITH TO FOLLOW WITH SAME. AS PER DOC. NO: AMNS-TCM-CDE-COMMON-0003. 1, ERECTION & DISMANTLING OF SCAFFOLDING -UP TO 30 MRT HEIGHT. QTY- 6968 M3 2,POWER TOOL CLEANING .- Surface Preparation SSPC ST2 | ST3 as per ISO 8501-1- 8000 M2 3, SUPPLY<(>&<)>APPLY OF EPOXY HB AL PRIMER - (Vs-80%, DFT 100-120 Primer Specification:- EIL F-8 - 8000 M2 4, SUPPLY<(>&<)>APPLY EPOXY HB MIO - MIO (Vs-80%, DFT 150-170 Specification:- Epoxy MIO | Epoxy Phenolic Coating - 8000 M2 5, SUPPLY<(>&<)>APPLY PU HB TOPCOAT -Vs-60%, DFT 50 -8000 M2 RED BROWN FOR THE HYDRAULIC PIPING. YELLOW GREEN FOR WATER PIPING. STRUCTURE – LIGHT BLUE. CRANE STRUCTURE - SILVER NG PIPE - ORANGE YELLOWISH DFT AROUND 450 Item 1- Painting of HSM basement structure and piping. Color – Red brown for the hydraulic piping. (RAL COLOR CODE-8001) Yellow green for water piping. (RAL COLOR CODE- 6010) Structure – light Blue. (RAL-5017) Compressed air line (RAL COLOR CODE -5012) Materials under contractor scope – Paint remover tools. One Coat Primer. (DFT 185 MICRONS) Two coats of polymer painting. (DFT around 450 MICRONS) Quality certificate by NACE certified engineer AM/NS India Standard coating documents is attached herewith to follow with same . Item2-painting of 15 columns in HSM shade Structure – light Blue. (RAL-5017) Materials under contractor scope – Paint remover tools. One coat Primer. Two coats of polymer painting. (DFT around 450) Quality certificate by NACE certified engineer Scaffolding -as an when required for height work. (Separately) Item 3- painting of crane maintenance structure. Height work around 27 meters Nose – 4 structures Page 2 of 3 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000115394 Date 25.06.2024 Submission Date 03.07.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Mr. Rutvik Dudakiya Contact Email RUTVIK.DUDAKIYA@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Services for line Item Quantity UOM Technical Details Other Details Color- silver (RAL -) Materials under contractor scope – Paint remover tools. One coat primer. ( DFT 185 MICRONS) Two coats of polymer painting. (DFT around 450 MINCRONS) Quality certificate by NACE certified engineer. MANLIFTER -As an when required for height work. (Separately) AMNS Standard coating documents are attached herewith to follow with same. Item-4 NG PIPELINE Color -ORANGE YELLOWISH(RAL-1004) STRUCTUTE – BLUE (RAL-5017) Materials under contractor scope – Paint remover tools. One coat Primer. (DFT 185 MICRONS) Two coats of polymer painting. (DFT around 450MICRONS) Quality certificate by NACE certified engineer Scaffolding -as an when required for height work. (Separately) AM/NS INDIA Standard coating documents is attached herewith to follow with same. * No Pedestrian/Cycles/Two Wheelers movement will be allowed inside the Plant Premises. * Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside plant premises. Vendors to ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. The movement of persons inside the plant by foot/bicycle/two wheelers is prohibited. * Associate must undergo Medical Fitness at our Care Nursing Home, AM/NS Township, Hazira. This would be done as per AM/NS India standards and the cost shall be borne by the vendor. AMNS has its own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. The Contractor Shall Be Responsible for Taking Corrective Action for Any Notices of Violations Issued As A Result Of The Contractors Or Any Subcontractors Actions Or Operations During The Performance of this contract. *Statutory requirement and require documentations providing and maintaining parts is in vendor Scope as per iso standard. Scope of Work- AM / NS Steel PROVIDING WORK PERMIT AND ISOLATION BEFORE START OF THE JOB ON NEED BASIS. WORK AT HEIGHT PERMIT. PROVIDING OF WATER, ELECTRICITY ON NEED BASIS. SPECIFIC PENALTY FOR NONPERFORMANCE BY VENDOR AND MUST BE CARDINALLY MEASURED IN CASE OF ANY VIOLATION REPLATED TO SAFETY, CONTRACTOR WILL BE PANELIZED AS PER THE COMPANY POLICY. ALSO DUE TO THE NONPERFORMANCE LIKE POOR QUALITY OF JOB, NON-AVAILABILITY OF MANPOWER & UN-NECESSARY DELAYS VENDOR WILL BE PENALIZED FROM CURRENT MONTHLY BILL ACCORDING TO THE CRITICALITY OF THE REASON. Specific Penalty for nonperformance by vendor and must be cardinally measured. Non-conformity of Work. Penalty will be imposed in case of noncompliance to HSE norms. Job - Specific Penalty Clause should be mentioned. - Poor workmanship/ Job failure /Poor Quality work As per Management Directive, transport / movement of associates to & fro for Plant should by mandatorily in 4 Wheelers and Buses. Bicycles and

Tender Notice

43897327

Indian


Gujarat

July 03, 2024

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Tender For Structure And Piping Corrosion - Hsm Plant 48010 10 10 10 Surface Preparation to ST-2 standard & 8,000 M2 20 SUPPLY&APPLY OF EPOXY HB AL PRIMER 8,000 M2 30 SUPPLY&APPLY EPOXY HB MIO 8,000 M2 40 SUPPLY&APPLY PU HB TOPCOAT 8,000 M2 50 SCAFFOLDING WITH MATERIAL ABOVE 20 MTR 6,968 M3 Email : SANJAY.SHIROYA@AMNS.IN Contact : Name : Sanjay Shiroya Item Details : SPR FOR HSM STRUCTURE AND PIPING CORROSION PROTECTION PAINTING-CY-2023. Scope of Work- Vendor SURFACE PREPARATION & PRIMARING & PAINTING. PAINTING OF BASEMENT STRUCTURE AND PIPING. PAINTING OF 15 COLUMNS IN HSM SHADE. PAINTING OF CRANE MAINTENANCE STRUCTURE. PAINTING OF NG PIPELINE ALL WORK AND SCOPE WILL BE AS PER ATTACHED DOCUMENTS. ALL PAINTING MATERIALS ARE IN VENDOR SCOPE. PAINT MAKE - NEROLAC / MORSAN OR EQUIVALENT. QUALITY CERTIFICATE BY NACE CERTIFIED ENGINEER. SCAFFOLDING - WHEREVER REQUIRED TAKE CARE BY VENDOR. AMNS STANDARD COATING AS WELL AS WORK DOCUMENTS ARE ATTACHED HEREWITH TO FOLLOW WITH SAME. AS PER DOC. NO: AMNS-TCM-CDE-COMMON-0003. 1, ERECTION & DISMANTLING OF SCAFFOLDING -UP TO 30 MRT HEIGHT. QTY- 6968 M3 2,POWER TOOL CLEANING .- Surface Preparation SSPC ST2 | ST3 as per ISO 8501-1- 8000 M2 3, SUPPLY<(>&<)>APPLY OF EPOXY HB AL PRIMER - (Vs-80%, DFT 100-120 Primer Specification:- EIL F-8 - 8000 M2 4, SUPPLY<(>&<)>APPLY EPOXY HB MIO - MIO (Vs-80%, DFT 150-170 Specification:- Epoxy MIO | Epoxy Phenolic Coating - 8000 M2 5, SUPPLY<(>&<)>APPLY PU HB TOPCOAT -Vs-60%, DFT 50 -8000 M2 RED BROWN FOR THE HYDRAULIC PIPING. YELLOW GREEN FOR WATER PIPING. STRUCTURE – LIGHT BLUE. CRANE STRUCTURE - SILVER NG PIPE - ORANGE YELLOWISH DFT AROUND 450 Item 1- Painting of HSM basement structure and piping. Color – Red brown for the hydraulic piping. (RAL COLOR CODE-8001) Yellow green for water piping. (RAL COLOR CODE- 6010) Structure – light Blue. (RAL-5017) Compressed air line (RAL COLOR CODE -5012) Materials under contractor scope – Paint remover tools. One Coat Primer. (DFT 185 MICRONS) Two coats of polymer painting. (DFT around 450 MICRONS) Quality certificate by NACE certified engineer AM/NS India Standard coating documents is attached herewith to follow with same . Item2-painting of 15 columns in HSM shade Structure – light Blue. (RAL-5017) Materials under contractor scope – Paint remover tools. One coat Primer. Two coats of polymer painting. (DFT around 450) Quality certificate by NACE certified engineer Scaffolding -as an when required for height work. (Separately) Item 3- painting of crane maintenance structure. Height work around 27 meters Nose – 4 structures Page 2 of 3 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000115394 Date 25.06.2024 Submission Date 03.07.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Mr. Rutvik Dudakiya Contact Email RUTVIK.DUDAKIYA@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Services for line Item Quantity UOM Technical Details Other Details Color- silver (RAL -) Materials under contractor scope – Paint remover tools. One coat primer. ( DFT 185 MICRONS) Two coats of polymer painting. (DFT around 450 MINCRONS) Quality certificate by NACE certified engineer. MANLIFTER -As an when required for height work. (Separately) AMNS Standard coating documents are attached herewith to follow with same. Item-4 NG PIPELINE Color -ORANGE YELLOWISH(RAL-1004) STRUCTUTE – BLUE (RAL-5017) Materials under contractor scope – Paint remover tools. One coat Primer. (DFT 185 MICRONS) Two coats of polymer painting. (DFT around 450MICRONS) Quality certificate by NACE certified engineer Scaffolding -as an when required for height work. (Separately) AM/NS INDIA Standard coating documents is attached herewith to follow with same. * No Pedestrian/Cycles/Two Wheelers movement will be allowed inside the Plant Premises. * Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside plant premises. Vendors to ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. The movement of persons inside the plant by foot/bicycle/two wheelers is prohibited. * Associate must undergo Medical Fitness at our Care Nursing Home, AM/NS Township, Hazira. This would be done as per AM/NS India standards and the cost shall be borne by the vendor. AMNS has its own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. The Contractor Shall Be Responsible for Taking Corrective Action for Any Notices of Violations Issued As A Result Of The Contractors Or Any Subcontractors Actions Or Operations During The Performance of this contract. *Statutory requirement and require documentations providing and maintaining parts is in vendor Scope as per iso standard. Scope of Work- AM / NS Steel PROVIDING WORK PERMIT AND ISOLATION BEFORE START OF THE JOB ON NEED BASIS. WORK AT HEIGHT PERMIT. PROVIDING OF WATER, ELECTRICITY ON NEED BASIS. SPECIFIC PENALTY FOR NONPERFORMANCE BY VENDOR AND MUST BE CARDINALLY MEASURED IN CASE OF ANY VIOLATION REPLATED TO SAFETY, CONTRACTOR WILL BE PANELIZED AS PER THE COMPANY POLICY. ALSO DUE TO THE NONPERFORMANCE LIKE POOR QUALITY OF JOB, NON-AVAILABILITY OF MANPOWER & UN-NECESSARY DELAYS VENDOR WILL BE PENALIZED FROM CURRENT MONTHLY BILL ACCORDING TO THE CRITICALITY OF THE REASON. Specific Penalty for nonperformance by vendor and must be cardinally measured. Non-conformity of Work. Penalty will be imposed in case of noncompliance to HSE norms. Job - Specific Penalty Clause should be mentioned. - Poor workmanship/ Job failure /Poor Quality work As per Management Directive, transport / movement of associates to & fro for Plant should by mandatorily in 4 Wheelers and Buses. Bicycles and